5
Biological Dosimetry at RERF

Unlike DS86, which provides a calculated estimate of a person’s organ dose, biological dosimetry estimates dose by evaluating a marker left in the tissue by radiation exposure. The marker can be any of a number of signatures or can be evidence of radiation damage itself. These markers are, in general, a function of the magnitude of an exposure, and they have for some time offered the promise of specific dose determination for each person exposed to ionizing radiation.

Efforts to determine biological doses of survivors in Hiroshima and Nagasaki began at RERF in 1968, shortly after cytogenetic dosimetry was first shown to be useful in radiation-dose reconstruction. However, not all markers of radiation exposure persist; the body repairs or deletes damage that is used as an indicator of exposure. For instance, the most reliable and best documented bioindicator of radiation exposure—the number of dicentrics in peripheral lymphocytes—persists for only about 3 years or less; although dicentrics are excellent for recent accidents, they are not useful for dose reconstruction in the Japanese survivors more than 50 years later. Therefore, biological dosimetry at RERF has had to turn to stable aberrations or other markers that persist for a lifetime. Until very recently, the assay of such persistent markers has been cumbersome and time-consuming, and this has resulted in biodoses for only a small fraction of the people in the Life Span Study (LSS) cohort.

Efforts to find faster assays and more reliable biomarkers of dose have led to RERF attempts to do work by conventional staining analysis and G-banding for cytogenetic aberrations, glycophorin-A assays, electron-spin resonance (ESR) of calcium-tissue samples, and fluorescence in situ hybridization (FISH) for the detection of reciprocal translocations in human chromosomes (See Table 5–1).

Table 5–1 summarizes a number of markers that have been used in biological dosimetry and compares their attributes. Most of these methods have been explored

Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×

TABLE 5–1 Comparison of Biomarker Attributes (Straume and Lucas 1995)

Biomarker

Human in vivo

in vitro

Animal Model

Inter-Person Variation

Persistence Post-Exposure

Translocationsa

Yes

Yes

Yes

Low

0-lifetime

Dicentrics

Yes

Yes

Yes

Low

0–6 mos.

Micronuclei

Yes

Yes

Yes

High

0–6 mos.

HPRTb

Yes

Yes

Yes

Medium

1 mo.−1 yr.

GPAc

50%

No

No

High

6 mo.-lifetime

TCRd

Yes

No

No

High

1 mo.−2yrs.

HLAe

50%

Yes

No

?

1 mo.−1 yr.

SCEsf

Yes

Yes

Yes

?

0–6 mos.

DNA Adducts

Yes

Yes

Yes

?

0–6 mos.

Protein Adducts

Yes

Yes

Yes

?

0–6 mos.

aReciprocal chromosome translocations.

bHypoxanthine phosphoribosyltransferase assay.

cGlycophorin-A somatic mutation assay.

dT-cell antigen receptor mutation assay.

eHuman leukocyte antigen mutation assay.

fSister chromatid exchanges.

at RERF and for various reasons, some obvious, many have not been suitable for the type of dose determination required.

Despite the promise of FISH and other new assays to produce the assay speed that would allow biodose determination for large numbers of survivors in the RERF study cohort, fewer than 4000 of the over 86,000 in the LSS population currently have biologically-determined doses. Most of these individual doses are derived from the very labor-intensive work with G-banding or from ESR. In addition to the biomarkers compared in Table 5–1, individual exposures to x or gamma radiation can be determined by using electron spin resonance to detect the physical signature left in tooth enamel by irradiation. The ESR signal is proportional to dose between 0.1 and 10 Gy and is independent of photon energy above 200 KeV. As such, ESR signals obtained from the teeth of survivors are good indicators of the doses from the high gamma ray energies released by the A-bombs. This technique has been used successfully to reconstruct dose in some radiation accidents (Pass and others 1997) and at RERF for a limited number of survivors (about 60). The comparison in Figure 5–1 of the dose derived from ESR and chromosome translocations for the same Japanese survivors shows excellent agreement within the uncertainties of these types of assay.

Given the small numbers of biodoses available and the labor currently involved in producing such individual doses, biological dosimetry is not currently a viable alternative to an overall dosimetry system that produces a dose estimate for all of the members of the LSS. Although only a small number of biologically-derived doses for people in the LSS cohort have been determined, these estimates

Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×

FIGURE 5–1 Translocation frequency of lymphocytes from 41 tooth donors measured by conventional Giemsa staining plotted against ESR-estimated gamma-ray dose for lingual portions of molars, (a) Individual data; (b) grouped data (each point consists of five individuals) (Nakamura and others 1998).

are important in finding out whether there are problems with DS86. As an independent individual dose assessment, biological dosimetry can help to characterize problems and suggest work that must be done to make any successor dosimetry system an accepted source of dose information. For example, areas where biological indicators of radiation dose and the doses derived from DS86 disagree can be looked for. Comparisons of specifically selected subsets of the LSS cohort can yield important evidence to support or refute discrepancies between DS86 and in situ physical activation measurements. Analysis of the trends in such comparisons can be vital clues as to the nature and direction of discrepancies. Two issues of DS86 accuracy in predicting dose are addressed with biological data: the possible underestimation of neutron doses in Hiroshima and the possible overestimation of gamma doses to workers in the Nagasaki torpedo factories.

Differences Between Hiroshima and Nagasaki

The first source of biological data, which has been interpreted by some as evidence of underestimation of neutron dose in Hiroshima, comes first from epidemiology, and second from biological dosimetry. The most recent analysis of cancer risk data from the LSS cohort suggests that excess cancer rates are higher in Hiroshima than Nagasaki (Pierce and others 1996). Interpretation of that observation is a contentious issue, and it can be attributed to various factors. Some have pointed to it as evidence that the more biologically injurious neutrons are the reason for a higher excess rate in Hiroshima than in Nagasaki, where the neutron doses are generally conceded to have been lower (see Chapter 7 for a discussion of this issue). The epidemiological observation is consistent with the biological dosimetry for the

Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×

two cities. Stram and others (1993) reported a greater number of stable chromosomal aberrations in the lymphocytes of members of the LSS cohort in Hiroshima than for the same DS86-estimated dose in Nagasaki. Analyses and explanations of these findings have looked to differences in the populations of the cities and to overall underestimation of the Hiroshima dose as possible explanations, but they have not been able to rule out the possibility that the difference is attributable to an underestimation of the neutrons in Hiroshima DS86 doses.

Recent analysis of stable chromosome aberration data obtained from Geimsastained cultures from approximately 3000 survivors in Hiroshima and Nagasaki confirms there is a statistically significant difference in the number of chromosome aberrations seen in the two cities at any given dose (Nakamura and Preston 2000). Survivors in Hiroshima had an average of 6.6% aberrant cells per sievert of exposure; whereas Nagasaki survivors had 3.7% aberrant cells per sievert (see Figure 5–2).

FIGURE 5–2 Scoring efficiency-adjusted proportion of cells with aberrations versus dose. The solid curve is a nonparametric estimate of the dose-response function (Kodama and others 2001).

Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×

The Nagasaki Factory Workers

A comparison of aberrations reveals inconsistencies between the number of aberrations and the shielding calculated for survivors in DS86. This is especially true for people located in the large metal torpedo factories in Nagasaki. These survivors had lower numbers of aberrations than individuals exposed to the same dose calculated by DS86 in Nagasaki houses, suggesting that DS86 over-estimates the doses to these people by approximately 40%. This observation agrees with previous ESR work based on the examination of tooth enamel.

When gamma-ray doses for the workers in the Nagasaki torpedo factories are determined with ESR (Nakamura 1999, 2000), they are 40–60% less than those estimated by DS86 (Preston 1999). The fundamental difference between this cluster of large sheet-metal factories filled with heavy machinery and the typical DS86 radiation-shielding case—a wood frame residence—has led to concern that DS86 does not adequately account for the shielding of the factory workers. If that is the case, it causes the current dosimetry system to overestimate the gamma-ray dose received by the roughly 800 workers in the factories. This does not seem like a large percentage of the 86,000 people in the LSS cohort, but such an overestimation becomes important when one recognizes that the 800 are about 40% of the survivors who received 0.5–2.0 Sv in Nagasaki. They are a large percentage of the moderate to high-dose survivors in Nagasaki and are therefore crucial to any accurate risk analysis that involves the Nagasaki data. Thus, it seems vital that any future work to upgrade the dosimetry system for RERF contain a state-of-the-art method of handling the shielding in complex structures. This matter is presently under investigation. Obviously, without biological dosimetry studies on these workers as a source of independent dose determination, the magnitude and direction of the possible miscalculation of the doses to the factory workers would not have been seen.

The limited amount of biological dosimetry that is available for the survivors in the RERF cohort has proven to be extremely useful. Biodoses have served to confirm a potentially significant difference between the two cities, which if substantiated could provide valuable information about the effect of the different qualities of radiation in the two cities (see Chapter 7). ESR and stable chromosome aberrations have highlighted important potential inadequacies in the shielding models currently used in DS86. Given the vital role that biological dosimetry played in this specific case, it is prudent to expand the number of cases in which it is used. Techniques like FISH and ESR that are in place at RERF could be extremely useful in providing an independent dose assessment for complex and uncertain shielding configurations. With careful controls for background aberration rates, FISH could potentially resolve the persistent differences in aberrations and effects observed for the two cities. ESR is equally valuable in cases where the gamma dose needs independent corroboration. Biodosimetry cannot currently replace the dose calculated for the entire LSS; but it does provide an invaluable source of dose evaluation for testing the integrity of DS86 or any subsequent dosimetry system.

Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×
Page 74
Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×
Page 75
Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×
Page 76
Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×
Page 77
Suggested Citation:"5. Biological Dosimetry at RERF." National Research Council. 2001. Status of the Dosimetry for the Radiation Effects Research Foundation (DS86). Washington, DC: The National Academies Press. doi: 10.17226/10103.
×
Page 78
Next: 6. Uncertainty in DS86 »
Status of the Dosimetry for the Radiation Effects Research Foundation (DS86) Get This Book
×
Buy Hardback | $61.00 Buy Ebook | $48.99
MyNAP members save 10% online.
Login or Register to save!
Download Free PDF

The Committee on Dosimetry for the Radiation Effects Research Foundation (RERF) was set up more than a decade ago at the request of the U.S. Department of Energy. It was charged with monitoring work and experimental results related to the Dosimetry System 1986 (DS86) used by RERF to reconstruct the radiation doses to the survivors in Hiroshima and Nagasaki. At the time it was established, DS86 was believed to be the best available dosimetric system for RERF, but questions have persisted about some features, especially the estimates of neutrons resulting from the Hiroshima bomb.

This book describes the current situation, the gamma-ray dosimetry, and such dosimetry issues as thermal-neutron discrepancies between measurement and calculation at various distances in Hiroshima and Nagasaki. It recommends approaches to bring those issues to closure and sets the stage for the recently convened U.S. and Japan Working Groups that will develop a new dosimetry for RERF.

The book outlines the changes relating to DS86 in the past 15 years, such as improved numbers that go into, and are part of, more sophisticated calculations for determining the radiations from bombs that reach certain distances in air, and encourages incorporation of the changes into a revised dosimetry system.

  1. ×

    Welcome to OpenBook!

    You're looking at OpenBook, NAP.edu's online reading room since 1999. Based on feedback from you, our users, we've made some improvements that make it easier than ever to read thousands of publications on our website.

    Do you want to take a quick tour of the OpenBook's features?

    No Thanks Take a Tour »
  2. ×

    Show this book's table of contents, where you can jump to any chapter by name.

    « Back Next »
  3. ×

    ...or use these buttons to go back to the previous chapter or skip to the next one.

    « Back Next »
  4. ×

    Jump up to the previous page or down to the next one. Also, you can type in a page number and press Enter to go directly to that page in the book.

    « Back Next »
  5. ×

    Switch between the Original Pages, where you can read the report as it appeared in print, and Text Pages for the web version, where you can highlight and search the text.

    « Back Next »
  6. ×

    To search the entire text of this book, type in your search term here and press Enter.

    « Back Next »
  7. ×

    Share a link to this book page on your preferred social network or via email.

    « Back Next »
  8. ×

    View our suggested citation for this chapter.

    « Back Next »
  9. ×

    Ready to take your reading offline? Click here to buy this book in print or download it as a free PDF, if available.

    « Back Next »
Stay Connected!