Committee Responses to the Government Accountability Office Report
A primary motivation for this study was the Government Accountability Office (GAO) report GAO-10-119 (GAO, 2009). In the report, the GAO recommended that “the Army should provide for an independent ballistics evaluation of the First Article Testing results,” that “the Army should assess the need to change its procedures based on the outcome of the independent experts’ review and document these and all other key decisions made to clarify or change the testing protocols,” and that “the Army provide for an independent external peer review of Aberdeen Test Center’s body armor testing protocol, facilities and instrumentation” (GAO, 2009, p. ii).
The committee has addressed questions raised by the GAO in its report, and its responses to seven specific items that were recommended for evaluation and action (GAO, 2009, pp. 37-38.) are summarized here. The committee took its charge to conduct an independent assessment very seriously.
The GAO report was thoughtful and pointed out a number of important issues. There was give and take between GAO, DoD, and the Army. On some issues, DoD and the Army agreed with GAO. On others, there was disagreement. The committee has listened to arguments on many sides of this debate. Its findings and recommendations are based on discussions not only with government experts but also with body armor manufacturers and commercial testers certified by the National Institute of Justice (NIJ).
The committee was precluded from using classified data. As a result, specific first article testing data based on real-world threats were not available to it. However, it spent many hours reading background information and being briefed by experts throughout the body armor community and believes that its findings and recommendations inform most of the important issues raised in the GAO report.
The committee’s overarching analysis of the report is that it was generally on target. Over time the Director, Operational Test and Evaluation (DOT&E) and the Army have adopted a number of the GAO recommendations. The committee has studied the report closely, discussed the issues with experts from throughout the body armor community, and agreed with several recommendations; it has taken a number of the issues to additional detailed levels with its findings and recommendations.
Below are the first 10 and last 10 pages of uncorrected machine-read text (when available) of this chapter, followed by the top 30 algorithmically extracted key phrases from the chapter as a whole.
Intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text on the opening pages of each chapter.
Because it is UNCORRECTED material, please consider the following text as a useful but insufficient proxy for the authoritative book pages.
Do not use for reproduction, copying, pasting, or reading; exclusively for search engines.
OCR for page 274
PREPUBLICATION DRAFT—SUBJECT TO EDITORIAL CORRECTION
Appendix F
Committee Responses to the Government Accountability
Office Report
A primary motivation for this study was the Government Accountability
Office (GAO) report GAO-10-119 (GAO, 2009). In the report, the GAO
recommended that “the Army should provide for an independent ballistics
evaluation of the First Article Testing results,” that “the Army should assess the
need to change its procedures based on the outcome of the independent experts’
review and document these and all other key decisions made to clarify or change
the testing protocols,” and that “the Army provide for an independent external
peer review of Aberdeen Test Center’s body armor testing protocol, facilities and
instrumentation” (GAO, 2009, p. ii).
The committee has addressed questions raised by the GAO in its report,
and its responses to seven specific items that were recommended for evaluation
and action (GAO, 2009, pp. 37-38.) are summarized here. The committee took its
charge to conduct an independent assessment very seriously.
The GAO report was thoughtful and pointed out a number of important
issues. There was give and take between GAO, DoD, and the Army. On some
issues, DoD and the Army agreed with GAO. On others, there was disagreement.
The committee has listened to arguments on many sides of this debate. Its
findings and recommendations are based on discussions not only with government
experts but also with body armor manufacturers and commercial testers certified
by the National Institute of Justice (NIJ).
The committee was precluded from using classified data. As a result,
specific first article testing data based on real-world threats were not available to
it. However, it spent many hours reading background information and being
briefed by experts throughout the body armor community and believes that its
findings and recommendations inform most of the important issues raised in the
GAO report.
The committee’s overarching analysis of the report is that it was generally
on target. Over time the Director, Operational Test and Evaluation (DOT&E) and
the Army have adopted a number of the GAO recommendations. The committee
has studied the report closely, discussed the issues with experts from throughout
the body armor community, and agreed with several recommendations; it has
taken a number of the issues to additional detailed levels with its findings and
recommendations.
-274-
OCR for page 274
PREPUBLICATION DRAFT—SUBJECT TO EDITORIAL CORRECTION
SUMMARY OF RESPONSES TO EVALUATION ITEMS AND ACTION
ITEMS RECOMMENDED FOR INDEPENDENT ASSESSMENT
Evaluation Item 1: The rounding of back-face deformation measurements
The Phase I report (NRC, 2009, p. 17) suggested that the DOT&E and the
Army adopt a common standard for rounding and indicating the appropriate
number of significant digits. The specific observation was that the Army should
consider using the American Society of Testing and Materials (ASTM) standard
ASTM E29-08, Standard Practice for Using Significant Digits in Test Data to
Determine Conformance with Specifications (ASTM, 2008). During briefings of
the Phase I report, both DOT&E and the Army said they agreed with the
recommendation.
Evaluation Item 2: Not scoring penetrations of material through the plate as
a compete penetration unless broken fibers are observed in the Kevlar
backing behind the plate
The Phase I committee was briefed by the COL Jeffrey Holt, Commander
of the Aberdeen Test Center (ATC). He said that the command wanted a
definition for a “complete penetration” that minimized subjectivity on part of the
tester and manufacturer. As a result, ATC adopted a convention that any test
round that penetrated the armor plate and continued on to completely break any
Kevlar fiber on the back of the shoot pack would be considered a complete
penetration. The committee felt this provided a consistent description for the body
armor community and virtually eliminated subjectivity when scoring a plate as
having been completely penetrated.
As defined in the new DOT&E protocol, “a complete penetration of the
test plate sample occurs on any fair record test shot impact in which the projectile,
any fragment of the projectile, or any fragment of the armor material is ejected
from the rear of the plate and passes into the first ply (minimum of one complete
yarn broken) of the soft armor (ballistic package) located behind the test plate
sample when it is placed into the soft armor test panel. The first ply of the soft
armor (ballistic package) shall serve as a witness plate.” (DOT&E, 2010, p. 4)
Evaluation Item 3: The use of the laser scanner to measure back-face
deformations without a full evaluation of its accuracy as it was actually used
during testing, to include the use of software modifications and operation
under actual test conditions
The Phase I committee was provided a copy of ATC Internal Operating
Procedure No. 001: Measurement of Backface Deformation (BFD) Using Faro®
Quantum Laser Scan Arm and Geomagic® Qualify® for Hard and Soft Body
-275-
OCR for page 274
PREPUBLICATION DRAFT—SUBJECT TO EDITORIAL CORRECTION
Armor, and found that it adequately describes the appropriate and consistent use
of the laser scanning system (Huber, 2009; NRC, 2009).
Additionally, the Phase I report stated that the “laser scanning system
(including the testing protocols, facilities and instrumentation) as currently
implemented by the Army (or for similar equipment) if used in accordance with
the Army’s procedures, is a valid approach for determining the contours of an
indent in a nontransparent clay material at a level of precision adequate for the
Army’s current ballistic testing of body armor.” (NRC, 2009, p. 13)
During Phase III the committee looked for improvements to procedures
that could result in more consistent measurements made with laser scanners.
There are several findings in the Phase III report that if implemented by DOT&E
and the Army, could improve consistency in laser scanning. For example, there is
software that allows for smoothing the raw digital data captured by the Faro. The
software has settings that allow for various levels of resolution. The committee
was shown that just by switching from one level of resolution to another resulted
in a 1 mm difference in measurement for the same backface deformation (BFD).
Manufacturers can be burdened, in this example, by a 1 mm penalty simply
because an operator has selected a particular setting. The committee finds that a
control study should be conducted to determine the most reasonable and
consistent Faro smoothing settings to be used while measuring BFDs in body
armor testing. Similarly, any software selections or system changes that could
cause a relevant change to BFD measurements should be studied. Participation in
this study should include, at a minimum, ATC, NIJ-certified private testing labs,
and body armor manufacturers.
Another finding in the Phase III report that relates to this issue is that there
needs to be a single measurement standard to determine the ability of any system
to measure a representative BFD regardless of different labs, measurement
instruments, and operators. Specifically, a standard model or a BFD artifact (as
initially recommended by the National Institute of Standards and Technology)
should be developed and used as part of this analysis. Previous work in this area
by ATC and by the National Institute of Standards and Technology had
established the importance of using an artifact to mimic the measurement process.
The committee believes that because the BFD measurement process is a
two-step process (measurement of the preshot surface and measurement of the
postshot BFD), both of these steps should be made with a single national standard
artifact. It is suggested that an artifact be made that mimics the preshot surface
with a flap that covers a multiple-BFD imprinted plate, or a flap on a helmet
surface that covers a model BFD crater. Such a model could be made of hard
plastic, or, a softer coating could be applied. While the thickness of the flap
would affect the absolute readings, the relative readings between labs and
operators would not be affected. This artifact would be used to confirm that any
change (e.g., hardware, software, or operator) still resulted in a consistent
measurement.
-276-
OCR for page 274
PREPUBLICATION DRAFT—SUBJECT TO EDITORIAL CORRECTION
Evaluation Item 4: The exposure of the clay backing material to rain and
other outside environmental conditions as well as the effect of high oven
temperatures during storage and conditioning
ATC demonstrated to the committee that the ovens used to condition the
clay prior to testing had been moved inside the testing range building to preclude
exposure of clay to rain and other outside weather.
The issue of high oven temperatures is more complicated. Back in the late
1970s, Roma Plastilina #1, a modeling clay developed for artists, calibrated at
room temperature when used for testing applications. Subsequently, the
composition of the clay changed over time to meet artists’ needs. As the
composition slowly changed, experimentation has shown the only way that the
calibration standard (25 mm ± 3 mm) could be achieved was by heating the clay.
As a rule of thumb, experienced test operators at NIJ -certified commercial testing
laboratories, who have decades of experience with clay, reported to the committee
that the clay has had to be heated about an additional 1°F each year to achieve
calibration standards.
Currently, there is an informal experimental effort at both ATC and the
commercial labs to attempt to restrict the temperature of the clay boxes to about
105°F.68 (Interestingly, for the Phase I body armor testing demonstrations at ATC
in December 2009, the temperature goal was approximately 104°F.) However, if
the clay formulation continues to change to meet artist expectations, it is likely
that the temperature of the clay will have to be increased or decreased to allow the
clay to properly calibrate.
Accordingly, the committee found that DOT&E and the Army should
urgently develop a standard formulation for ballistics backing material that allows
calibration at room temperature, as was the case when body armor testing using
clay began. Additionally, as a medium-term goal, the committee found that
DOT&E and the Army should research an alternative to the current Roma
Plastalina #1 that not only calibrates at room temperature but also minimizes the
effect of human working (thixotropy).
By standardizing a ballistics backing material formulation that minimizes
the variation caused by temperature and thixotropy the committee feels that the
body armor community will have eliminated a significant amount of the variation
in the body armor testing process. Historically (and incorrectly) all variation in
the testing process has been assumed to be due to body armor plates
inconsistencies. The practical result of a standard ballistics backing material
formulation as just described could be the production of lighter body armor that
still provides the same level of soldier protection.
68
Confirmed during personal communication between Larry Lehowicz, Committee chair,
and Travis Humiston, ATC, October 28, 2010.
-277-
OCR for page 274
PREPUBLICATION DRAFT—SUBJECT TO EDITORIAL CORRECTION
Evaluation Item 5: The use of an additional series of clay calibration drops
when the first series of clay calibration drops does not pass required
specifications
ATC test operators demonstrated the clay calibration process during each
phase of the study. Concerning the actions to repair and recondition clay boxes,
which include using additional clay calibration drops when the first series of clay
calibration drops did not pass specifications, the Phase I committee agreed that
test operators were following “procedures that are consistent with standard
practice by artists and others for filling space without entrapping air. That is,
small additions are made sequentially and each is heavily sheared by hand to
express any entrapped air. This procedure represents good practice.” (NRC, 2009,
p. 15)
Rheologists on the committee appreciate that there are many variables and
unknowns in clay calibration that need to be investigated by DOT&E and the
Army. The Phase II report (NRC, 2010) contains several findings and
recommendations pertaining to calibration and the drop test. Some of the
committee’s calibration-related findings are these:
Until a standard ballistics backing material that calibrates at room
temperature is developed, the body armor testing community should
conduct a posttest calibration drop to ensure that the clay has remained
in calibration.
Evaluate measurement differences when calibrations are made on the
side of the box and when they are made at the center of the box.
Conduct calibration experiments with a gas gun to better replicate the
projectile velocity and penetration depth that create a BFD.
Ensure pre- and postshot calibration consistency.
Investigate the effects of box size and shape on calibration results.
Action Item 1: Determine whether those practices that deviated from
established testing protocols during First Article Testing will be continued
during future testing and change the established testing protocols to reflect
those revised practices
The committee chair was told by senior Army staff members that the
Army would appoint a knowledgeable person to conduct an independent
assessment of the practices mentioned in the GAO report.
-278-
OCR for page 274
PREPUBLICATION DRAFT—SUBJECT TO EDITORIAL CORRECTION
Action Item 2: Evaluate and re-certify the accuracy of the laser scanner to
the correct standard with all software modifications incorporated and
include in this analysis a side-by-side comparison of the laser measurements
of actual back-face deformations with those taken by digital caliper to
determine whether laser measurements can meet the standard of the testing
protocols
The committee spent considerable time with ATC and NIJ-certified
commercial testing labs to better understand the advantages and disadvantages of
the digital caliper and the laser scanner. See Chapter 5 and Appendix M.
REFERENCES
ASTM (American Society for Testing and Materials). 2008. ASTM E29-08
Standard Practice for Using Significant Digits in Test Data to Determine
Conformance with Specifications. West Conshohocken, Pa.: ASTM
International.
DOT&E (Director, Operational Test and Evaluation). 2010. Standardization of
Hard Body Armor Testing. Memorandum dated April 27, 2010. Arlington,
Va.: Director, Operational Test and Evaluation.
GAO (United States Government Accountability Office). 2009. GAO-10-119.
Independent Expert Assessment of Army Body Armor Test Results and
Procedures Needed Before Fielding. Washington, D.C.: Government
Accountability Office.
Huber, J. 2009. Internal Operating Procedure No. 001: Measurement of Backface
Deformation [BFD] Using Faro® Quantum Laser Scan Arm and Geomagic®
Qualify® for Hard and Soft Body Armor. Aberdeen Proving Ground, Md.:
Aberdeen Test Center.
NRC (National Research Council). 2009. Phase I Report on Review of the Testing
of Body Armor Materials for Use by the U.S. Army: Letter Report.
Washington, D.C.: National Academies Press.
NRC. 2010. Phase II Report on Review of the Testing of Body Armor Materials
for Use by the U.S. Army. Washington, D.C.: National Academies Press.
-279-