Cover Image

Not for Sale



View/Hide Left Panel
Click for next page ( 27


The National Academies | 500 Fifth St. N.W. | Washington, D.C. 20001
Copyright © National Academy of Sciences. All rights reserved.
Terms of Use and Privacy Statement



Below are the first 10 and last 10 pages of uncorrected machine-read text (when available) of this chapter, followed by the top 30 algorithmically extracted key phrases from the chapter as a whole.
Intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text on the opening pages of each chapter. Because it is UNCORRECTED material, please consider the following text as a useful but insufficient proxy for the authoritative book pages.

Do not use for reproduction, copying, pasting, or reading; exclusively for search engines.

OCR for page 26
26 Fire Protection Association (NFPA) requirements applicable tors from one government agency see a violation that is at the time of construction or modification. Compliance with outside their jurisdiction, they typically notify other regulat- these requirements is your agency's responsibility. A prac- ing agencies. Inspectors also monitor compliance via reports tice that incorporates proper maintenance and inspection pro- submitted from accidents or injuries, emission citations trig- cedures for all facilities will help ensure compliance. Keep in gered by smoking buses, and public complaints made by mind that any modifications made to structures covered by employees and neighbors. the UBC or NFPA requirements must comply with current Consequences of noncompliance range from a minor codes and must be permitted and properly inspected if mod- infraction, with a notice to correct without imposing penal- ified or rehabilitated. ties, to large fines. In some cases sanctions include with- holding federal or state funds and/or criminal charges if your agency is found to be negligent and causing injury, death, or Fire Marshal excessive harm to the environment. The local fire marshal typically has authority for inspect- ing all buildings and equipment to verify compliance with CONTACT LIST state and local fire codes. Inspections typically include storage of flammable materials, fire alarms and safety sys- USDOT tems, extinguishers, and sprinklers. Maintenance and in- spection practices should include procedures for all fire and Mail: life safety items and for flammables and combustibles. The 400 7th Street, SW procedures should document compliance with these codes. Washington, DC 20590 Inspection documents must be on file and readily available for audits. Telephone: 202-366-4000 COMPLIANCE CHECKLIST Internet: The following is a checklist of important federal, state, www.dot.gov/contact.html and local regulatory organizations that promulgate regula- For CFR requirements go to www.archives.gov/ tions that typically affect bus maintenance. Agencies are federal_register/index.html urged to use the contact information provided below to become more familiar with these organizations and their requirements. Mail: To order CFR documents write to: Federal Superintendent of Documents CFR 49 Parts 393 and 396 P.O. Box 371954 EPA Pittsburgh, PA 15250-7954 OSHA FTA (if your agency is a grantee of federal funds) Telephone: State 202-512-1800 DOT EPA OSHA FMVSS UBC and NFPA Local Mail: Fire marshal 400 7th Street, SW, Room 6124 Building inspector Washington, DC 20590 Environmental agency (and local air district if applicable) Telephone: 888-327-4263 202-366-2746 COMPLIANCE MONITORING Regulatory agencies have several ways of monitoring Internet: compliance, including site visits and inspections. If inspec- www.nhtsa.gov/