Appendix C has two parts, which are taken from the survey 18. What year was the tunnel built or expected date of
results. The first part contains the national data and the second completion?
part is the international data. Some of the tunnels may make See below chart
multiple choices for the "please check all that apply" ques-
tions. The survey data below are shown based on the number 19. Is the tunnel under supervision?
of tunnels, instead of number of agencies (which may cover Yes, 24 hr--19
multiple tunnels). Yes, except at night--0
No--11
PART 1: NATIONAL DATA 20. What is the normal traffic operation?
Uni-directional--26
Section 1 Background Information
Bi-directional--4
The first 15 questions were used so that the researchers could
contact the respondent for additional information, if neces- 21. When does the tunnel operate in bi-directional
sary. All this information is shown below. mode? (Please check all that apply.)
Normally--4
At night time--2
Section 2 General Information Off-peak hours--2
Occasionally--0
Questions 16 and 17 were used to obtain the agency name During construction/maintenance in other tube--9
and the name of the tunnels, respectively. All this informa- Never--16
tion is shown below. Other (Please explain)--1 (emergency evacuation)
Number of
Tunnel agency
surveys
name
submitted Number of tunnels Year tunnel was built
1) Downtown Tunnel (First)--EBL 1) 1986
2) Downtown Tunnel (First)--WBL
3) Hampton Roads Bridge Tunnel-- 2) 1952
EBL
Virginia 4) Hampton Roads Bridge Tunnel-- 3) 1974
Department of WBL
7
Transportation 5) Midtown tunnel 4) 1958
(VDOT) 6) MonitorMerrimac Memorial Bridge
Tunnel
7) NAS Runway #29 Underpass 5) 1962
6) 1992
7) 1977
California 6 1) Webster Tube 1) 1963
Department of 2) Posey Tube 2) 1927
Transportation 3) Sunrise On Ramp 3) 2006
4) Caldecott Tunnel Complex #1 4) 1937
5) Caldecott Tunnel Complex #2 5) 1937
6) Caldecott Tunnel Complex #3 6) 1963
1) Liberty Tunnel 1) 1924
PennDOT 2
2) Stowe Tunnel 2) 1909
CDOT--Region Eisenhower/Johnson Memorial Tunnel 1973/1979
1, Maintenance 1 (2 bores, 1 tunnel unit)
Section 9
Chesapeake Bay 1) Thimble Shoals 1) 1964
2
Bridge and Tunnel 2) Chesapeake Channel 2) 1964
Maryland 1) The Fort McHenry Tunnel 1) 1985
Transportation 1 2) The Baltimore Harbor Tunnel 2) 1957
Authority
(continued on next page)
OCR for page 137
139
1) Oneonta 1) 1914
2) Cape Creek 2) 1921
3) Elk Creek 3) 1932
4) Toothrock 4) 1932
Oregon DOT 1 5) Arch Cape 5) 1937
6) Salt Creek 6) 1938
7) Sunset 7) 1940
8) Knowles Creek 8) 1958
9) Vista Ridge Twin Tunnels 9) 1969
The Port The Holland Tunnel 1927
Authority of New
1
York & New
Jersey
1) I-90 Mt. Baker Ridge Tunnel 1) 1990
WS DOT 1
2) I-90 Mercer Island Tunnel 2) 1990
22. What type of vehicles use the tunnel? (Please 26. Were there any casualties from the fire?
check all that apply.) None--16
Cars--24 Minor--2
Buses--24 Major--0
Trucks--24
HGV--19 27. Has the fire department ever been involved in
Special trucks (military)--12 fire fighting in this tunnel?
Gasoline tankers: freely--6 Never--1
Gasoline tankers: supervised when tunnel is closed Occasionally--1
for normal traffic--4 Every time--14
Other vehicles--10
28. Was there an investigation performed after the fire?
Section 3 Fire Incidents Information Every time--6
Occasionally, depending on fire size--6
23. How many annual vehicle fire incidents happen Never--1
in this tunnel (average)? Once (Please explain when)--5
No occurrence (skip questions 918)--11
Happened once in lifetime--0 29. What was the estimated maximum fire size?
Less than one every year--2 MD (2 tunnels)--Single tractor trailer truck
From 1 to 2 every year--14 CO--15 to 20 MW
From 2 to 5 every year--1 CA (5 tunnels)--small car fire
Happens at least once a month--0
30. What was the longest duration of the fire?
24. What were the most severe vehicle fire incidents
MD (2 tunnels)--about 20 min
in this tunnel? (Please check all that apply.)
CO--25 min
Motorcycle fire--0
WA (2 tunnels)--15 min
Passenger car fire--13
Multiple passenger cars (24 vehicles)--7
Vans--6 31. Have you videotaped any car fire incidence?
Bus--1 VA DOT (6 tunnels)--Yes
Heavy goods truck fire--10 VA DOT (1 tunnel)--No
Multiple trucks fire--0 PA DOT--No
Tanker fire--0 MD (2 tunnels)--No
Alternative fuel vehicle--0 NY/NJ Port Authority--Yes
Other--1 (Recreational vehicle, motor home) CO--No
WA DOT (2 tunnels)--Yes
25. Was there any damage made to this tunnel as a
result of the fire incident? 32. Can you share the video information?
No damages. No impact on tunnel operation--2
No damages. Tunnel was closed for operation for 33. Has your agency been successful in managing the
30 min or more--0 fire event? (Please provide an explanation.)
Minor damages (no structural damage)--15 No--0
Structural damage which required tunnel closure for Yes--13
an extended period of time--1 Partially--6
OCR for page 137
140
34. Do you have an emergency response plan in place? Fire sprinkler system--2
Yes--22 Foam system--4
Fire apparatus in the tunnel--1
35. Please explain what are the strengths of your
agency's fire management program? 40. What kind of fire life safety system does this
PA DOT--local response time under 10 min tunnel have? (Please check all that apply.)
PA DOT--EMS/FIRE response under 10 min Tunnel ventilation--20
MD (2 tunnels)--Exhaust fan fire pattern moved Emergency egress--9
smoke away from motorists caught behind the fire Egress pressurization--2
and the fire department responded quickly to Other (Please explain)--0
extinguish the fire. The quick response was the
result of quarterly meetings between the fire depart- 41. What communication systems are used by rescue
ment and the Authority to discuss response plans. personnel and others for fire emergency?
NY/NJ Port Authority--Coordination of multiple VA DOT (6 tunnels)--STARS
entities PA DOT--800mhz radio
VA CBBT (2 tunnels)--3,000 gallon tanker truck, MD (2 tunnels)--Portable radio and cellular phone
wrecker fire trucks, wall fire extinguishers, fire OR DOT (9 tunnels)--Radio, cell phone
pumps, fire department within 7 miles NY/NJ Port Authority--Radio
WA DOT--Routine testing VA CBBT (2 tunnels)--District radio, cell phone
statewide radio system
36. What barriers or difficulties have you or your CA DOT (5 tunnels)--call boxes and responding
organization encountered in implementing fire agency comms
management? (Please check all that apply.) CA DOT (1 tunnel)--responding agency comms
Technical (please explain)--2 WA DOT--Portable radio
Political (please explain)--1
Legal (please explain)--0 42. Please explain how quickly your agency is able
Organizational/institutional (please explain)--9 to detect and clear routine traffic crashes inside
Staffing/resources (please explain)--9 this tunnel?
Other (please explain)--0 VA DOT (7 tunnels)--1/2 h to 1 h for routine vehicu-
None--15 lar incidents; 4 h for incidents involving fatalities
PA DOT--less than 15 min tow trucks on site
37. What are your suggestions on how these barriers MD (2 tunnels)--Detection less than 1 minute
can be overcome? Clearing approx. 20 minutes; or more depending
NY/NJ Port Authority--Continuous training and on nature of crash and involvement of injuries
revision of policy OR DOT (9 tunnels)--Could take 1 h up to 8 h
WA DOT--More specific training for operations NY/NJ Port Authority--Detection is continuous
and maintenance staff. and almost instantaneous
VA CBBT (2 tunnels)--Normally less than 20 min
Section 4 Fire Detection, Fire Protection,
43. Do you have tow trucks in your agency or do you
Communication
contract out for theses services?
38. What kind of fire detection system does the tun- Have tow trucks--14
nel have? (Please check all that apply.) Contract out for tow trucks--10
Heat Detection (linear)--4 Other (Please explain)--6
Heat Detection (other than linear)--0
Smoke Detection--0 44. Are you concerned that your tunnel may not have
Pull Station--14 an adequate fire/life safety system to manage a
CCTV--18 significant fire event? Please explain.
Video surveillance technology--4 No--12
Phones--16 Yes--19
Other (Please explain)--0
Section 5 Design
39. What kind of fire protection system does the tun-
nel have? (Please check all that apply.) 45. Does your agency have their own standard for
Fire hydrants along the tunnel--11 tunnel design and for fire rating?
Standpipe system with fire hose connections Yes--3
(dry or wet)--17 No--28
Fire extinguishers in the tunnel--20 Other (Please explain)--0
OCR for page 137
141
46. What guidance and standards are provided to OR DOT (9 tunnels)--None
designers to address the fire design issues for NY/NJ Port Authority--Coordinate with agency
new and for retrofitted tunnels? (Please check all staff, other agency facilities, police at all levels,
that apply.) other agencies, OEM, and local authorities.
NFPA 502--23 VA CBBT (2 tunnels)--All traffic is held at the toll
ASHRAE--0 plazas and emergency crewmen stop traffic at the
FHWA--22 mouth of the tunnel.
Other (Please explain)--6 CA DOT (6 tunnel)--Standard traffic operations,
including traffic control and law enforcement
47. Do you specify the design fire size and fire curve to
the designers? (Please check all that apply.) 53. Do you have an emergency response plan in place?
Fire Size--9 Yes--31
Fire Curve--0 No--0
Require to follow the NFPA 502--17 Other (Please explain)--0
Leave it up to the Consultant--11
Leave it up to the Authority Having Jurisdiction 54. Which agency has the role of incident commander?
(AHJ)--7 VA DOT (7 tunnels)--State police or local responders
Other (Please explain)--1 PA DOT (2 tunnels)--local EMS/state police
MD (2 tunnels)--We are the incident commanders.
48. Is security blast design included in the OR DOT (9 tunnels)--Oregon DOT
requirements? (Please check all that apply.) NY/NJ Port Authority--Depends on emergency and
Security--9 location
Blast design--0 VA CBBT (2 tunnels)--Operations
Security and blast design--1 CA DOT (6 tunnels)--State and fire responders
WA DOT--Local fire department
49. Who is the Authority Having Jurisdiction (AHJ)?
Our Agency--25 55. What best practices can you share in the areas of
Fire Department--6 prevention, mitigation, and recovery from fire
Don't know--0 incidence?
Other (Please explain)--0 VA DOT (7 tunnels)--Perform "after-incident"
reviews
50. Do you apply a risk assessment approach for fire MD (2 tunnels)--Mitigation/recovery--Work
engineering? closely with local fire departments; our staff
Yes--10 that does towing, and contract towers to quickly
No--20 extinguish the fire and get the burned vehicle,
Other (Please explain)--0 and maintenance staff to clean up debris.
OR DOT (9 tunnels)--None
51. How do you handle specific risk that cannot be NY/NJ Port Authority--All if permission and
mitigated? non-disclosure agreements are granted
MD (2 tunnels)--Response and recovery plans
NY/NJ Port Authority--Conduct series of "table 56. Would you consider protection of the tunnel with
top" drills with agency staff, OEM, and local the fixed fire suppression system (sprinkler system)
authorities to meet the new NFPA 502 Max Fire Heat Release
CA DOT (6 tunnels)--Engineering judgment with Rate Requirements, if proven effective?
AHJ approval Yes--16
No--6
52. What traffic management and safety innovations Other (Please explain)--9
are deployed or planned to minimize or eliminate
problems such as congestion and traffic manage- 57. Have you identified gaps in research and design for
ment during a fire? tunnel fire safety, or fire detection and protection?
PA DOT (2 tunnels)--Detours are in place No--29
MD (2 tunnels)--Traffic is held prior to entering the Yes (Please explain)--2
impacted tunnels as soon as a fire is reported.
Detour routes are pre-planned and signed. All 58. Can you suggest strategies to eliminate the gaps
entry points to the tunnel throughway have and improve tunnel fire safety?
dynamic message signs and traffic is warned MD (2 tunnels)--Consider co-development of
prior to entering when major incidents impact specifications (industry standards) for the devices
the tunnel. along with the fire-code requirements such that
OCR for page 137
142
reliable and maintainable devices are commercially VA DOT (7 tunnels)--Emergency response manuals
available that are designed for the tunnel environ- are posted in each tunnel's control room and staff
ment. Consider the typical tunnel cleaning/ are expected to be familiar with the manuals.
washing operation, chemicals and pollutants PA DOT (2 tunnels)--Yearly review with first
present, and dirt/debris build up (e.g., locating a responders
commercially available pull station system for the MD (2 tunnels)--Quarterly meetings with local fire
roadway tunnel application that is reliable over a department, Authority Police and Authority
long time period has proven difficult). Maintenance Operations staff.
OR DOT (9 tunnels)--ODOT has an emergency
59. Would you consider a fire event to be similar to a drill every two years for first responders.
seismic event for design purposes? (Example NY/NJ Port Authority--Bi-annual fire response
design for the fire event which has a high simulation in the tunnel
probability to happen once in 500 years or VA CBBT (2 tunnels)--Monthly safety meetings
2,500 years?) CA DOT (6 tunnels)--No formal tunnel fire training;
Yes--22 department staff are required to adhere to require-
No--12 ments of department safety manual and procedures.
Other (Please explain)--1 WA DOT (2 tunnels)--Very little
60. What is this tunnel life's expectancy? 64. Would you need additional training tools for
VA DOT (7 tunnels)--Design life is 50 years; operators to manage a fire?
however, life expectancy typically exceeds Tunnel fire/systems simulator--19
100 years. No--11
PA DOT (2 tunnels)--150 years Other (please explain)--0
MD (2 tunnels)--100 years is the accepted life
expectancy 65. What equipment and materials are pre-positioned
OR DOT (9 tunnels)--100 years for response and recovery to a fire, such as for
VA CBBT (2 tunnels)--Depends on the amount the quick removal of disabled vehicles?
of maintenance performed VA DOT (7 tunnels)--Wreckers equipped with
materials to contain spills.
61. Do you have any additional suggestions and PA DOT (1 tunnel)--Tow trucks on site
thoughts on the design for fire emergency? PA DOT (1 tunnel)--None
PA DOT (2 tunnels)--see T-20's work MD (2 tunnels)--Tow vehicles are present on site.
NY/NJ Port Authority--Not at this time Fire extinguishers.
OR DOT (9 tunnels)--None
62. Please identify any research that you would like NY/NJ Port Authority--Equipped emergency
to see performed to help in the implementation response vehicle and towing vehicles
of fire safety systems. VA CBBT (2 tunnels)--Wreckers and fire trucks
PA DOT (2 tunnels)--see T-20's work are at the end of each tunnel
MD (2 tunnels)--Dirt build up in the fresh air CA DOT (5 tunnels)--1. fire extinguishers;
supply ducts. When fans moved to high for 2. operations center monitors CCTV
testing or during fires the dirt/dust gets blown up. CA DOT (1 tunnel)--None
This resembles smoke on CCTV images and it WA DOT (2 tunnels)--Incident response trucks for
reduces visibility. It is unknown if this causes removal of debris and disabled vehicles.
other concerns for either the public or emergency
responders. 66. What is considered an acceptable response time?
OR DOT (9 tunnels)--We need a national design VA DOT (7 tunnels)--1015 minutes
fire size, duration, and heat rating. PA DOT (1 tunnel)--<3 min tow truck, <10 min EMS
NY/NJ Port Authority--Implementation of a Foam PA DOT (1 tunnel)--less than 5 min, EMS less than
Delivery System 10 min
MD (2 tunnels)--35 minutes
OR DOT (9 tunnels)--20 minutes
Section 6 Operation, Maintenance, Repair, VA CBBT (2 tunnels)--5 minutes
Rehabilitation WA DOT (2 tunnels)--35 minutes
63. What types of exercises and other training are 67. How often are tunnels and emergency response
provided to staff and first responders to ensure equipment inspected and tested?
proficiency in response to an incident and how is PA DOT (1 tunnel)--Daily
the training evaluated? MD (2 tunnels)--Quarterly
OCR for page 137
143
VA CBBT (2 tunnels)--Once every 8 hours 71. What are the operational protocols for the use of
CA DOT (6 tunnels)--CO monitors--yearly; fire the ventilation system during a fire event?
standpipes--5 years VA DOT (7 tunnels)--Control room personnel
WA DOT (2 tunnels)--Varies depending on the identify location of fire (using touch screen) and
equipment. Could be weekly or yearly or 5 years emergency ventilation modes are activated
for structural items. accordingly.
PA DOT (1 tunnel)--All fans are to be run on high
68. What methods are used to inspect the structural speed until directed otherwise by fire & rescue.
integrity of the tunnel structure both routinely MD (2 tunnels)--The current control systems have
and after a fire? What materials are used to been programmed with fire-response plans that
repair concrete after a fire? automate the implementation of fire patterns.
VA DOT (7 tunnels)--Visual inspection and sound- Operators can focus on coordinating the man-
ing. Concrete is typically repaired with higher power using the CCTV to provide situational
strength concrete. awareness and immediately develop scope and
PA DOT (2 tunnel)--a) bridge inspectors are called scale needs for the emergency response. Opera-
to use techniques used during a bridge inspection. tors also can access the regional ITS to imple-
b) concrete; shotcrete ment appropriate traffic controls and warnings.
MD (2 tunnels)--Tunnels are inspected annually as VA CBBT (2 tunnels)--Operations at the incident
part of our facility inspection program and are give requirements at the ventilation building for
inspected by our structural engineers immediately each incident
following a fire. CA DOT (6 tunnel)--automatic operation based on
OR DOT (9 tunnels)--Sounding CO exposure limits with emergency override by
VA CBBT (2 tunnels)--Consultant engineers
responding AHJ
inspect the tunnels every year. We have not had
WA DOT (2 tunnels)--Fans will ramp up to draw
to repair any fire damage.
smoke and heat away from roadway.
CA DOT (6 tunnels)--Structural inspection 2 years
with visual inspection
72. How are the maintenance considerations worked
into the design elements of tunnel fire detection
69. If you were to start a new tunnel project, what
and fire suppression systems?
key elements would you incorporate in the design
PA DOT (1 tunnel)--Controls are put in an accessible
and construction to aid you in tunnel fire inci-
area.
dent management?
VA DOT (6 tunnels)--Sprinkler system and MD (2 tunnels)--Detections systems focus on traffic
automatic fire detection system. flow. Fires in the roadway always impact traffic
PA DOT (1 tunnel)--Nothing: fire department EMS and video based analytics detect abnormal traffic
response time under 10 minutes conditions within seconds. We have found smoke
PA DOT (1 tunnel)--Nothing: we have fire depts. very detection analytics to false alarm too much. Keep-
close to our tunnels that can respond in 5 to 10 min. ing false alarm rates low (below 3040%) of total
MD (2 tunnels)--All required elements from NFPA alarms is a must to maintain operator trust and
502. Control systems to automate fire pattern involvement. Fire suppression systems are acces-
implementation. CCTV or other fire spread detec- sible for maintenance inspection and utilize heat
tion in fresh air duct, sump pits, and exhaust air systems to address freezing issues.
ducts. Public communications system (FM broad- CA DOT (6 tunnels)--There must be access for
cast, PA system, electronic signs, or other means) maintenance
to instruct the public caught behind the incident. WA DOT (2 tunnels)--Through a collaborative
OR DOT (9 tunnels)--Detection equipment and process between Maintenance and Design offices
video surveillance
CA DOT (6 tunnels)--in accordance with NFPA 73. Do you actively screen or otherwise monitor truck
502 and AHJ cargoes entering the tunnel without disrupting the
WA DOT (2 tunnels)--Mandatory fire system sim- traffic flow?
ulator and monthly training for operations staff. Yes--15
No--15
70. Are the lighting and emergency communication Other (Please explain)--0
system designed to survive major fire events?
Yes--11 74. What dangerous cargo is acceptable and how is
No (please explain how to ensure safe evacuation this enforced?
during an incident that involves major fires)--17 VA DOT (7 tunnels)--Voluntary inspections based
Other (Please explain)--2 on truck placard information
OCR for page 137
144
MD (2 tunnels)--Propane tanks 20 lb or larger are PART 2: INTERNATIONAL DATA
not allowed. Gasoline tankers are not allowed.
Section 1 Background Information
Police monitor and enforce with tickets.
OR DOT (8 tunnels)--Unrestricted. Signs are in place
The first 15 questions were used so that the researchers could
and restrictions are posted on the ODOT web page.
contact the respondent for additional information, if neces-
Law enforcement monitors occasionally.
sary. All this information is shown below.
OR DOT (1 tunnel)--Flammable cargo is not
allowed in the Vista Ridge Tunnels.
VA CBBT (2 tunnels)--No dangerous cargo is Section 2 General Information
permitted.
CA DOT (6 tunnels)--Traffic laws are required to Questions 16 and 17 were used to obtain the agency name
enforce vehicle restrictions and the name of the tunnels, respectively. All this informa-
WA DOT (2 tunnels)--All cargo tion is shown below.
75. What systems do you have plans for repair or 18. What year was the tunnel built or expected date
replacement of fire or life safety equipment? of completion?
(Please check all that apply.) See chart below
Tunnel ventilation--8
Fire suppression--0 19. Is the tunnel under supervision?
Standpipes--8 Yes, 24 hr--7
Fire detection--0 Yes, except at night--0
Communication--8 No--0
Emergency lighting--6
Other (Please explain)--0 20. What is the normal traffic operation?
Uni-directional--6
Section 7 Follow-up
Bi-directional--1
76. Please provide any additional information or sug- 21. When does the tunnel operate in bi-directional
gestions you may have. mode? (Please check all that apply.)
PA DOT (2 tunnels)--Please see info from Normally--2
AASHTO T-20 including the 2005 European At night time--0
Tunnel Scan and the 2009 Domestic Tunnel Scan Off peak hours--0
CA DOT (3 tunnels)--Gasoline Tankers--freely Occasionally--0
only from (3 a.m.5 a.m.) During Construction/Maintenance in Other
tube--0
The last 2 questions were used so that the researchers could Never--4
contact the respondent for additional information, if necessary. Other (Please explain)--0
No. of
Tunnel agency
surveys
name
submitted No. of tunnels Year tunnel was built
Korea Expressway 1) Jookryung 1) 2001
Corporation 2 2) Average data for 280 (555 tubes) 2) From 1970 till present
(Korea) tunnels
Mak Hungary M6 South Completed in March 2010
1
(Hungary)
Ministère des Ville-Marie & Lafontaine 1976 and 1967
transports du 1
Québec (Canada)
Swedish Road Gota Tunnel 2006
1
Administration
Sydney Harbour Sydney Harbour Tunnel 1992
Tunnel Company 1
(Australia)
Vägverket Södra Länken 2004
1
(Sweden)
OCR for page 137
145
22. What type of vehicles use the tunnel? (Please 28. Was there an investigation performed after
check all that apply.) the fire?
Cars--7 Every time--3
Buses--7 Occasionally, depending on fire size--1
Trucks--7 Never--0
HGV--5 Once (Please explain when)--1
Special Trucks (military)--3
Gasoline Tankers: freely--4 29. What was the estimated maximum fire size?
Gasoline Tankers: supervised when tunnel is closed Swedish Road Administration: Sweden--8 MW
for normal traffic--0 Korea Expressway Corporation (280 tunnels):
Other Vehicles--1 South Korea--1 to 57 MW
Ministère des transports du Québec (1 tunnel,
2 bores):
Section 3 Fire Incidents Information
Canada--20 MW
Sydney Harbour Tunnel Company: Australia--3 MW
23. How many annual vehicle fire incidents happen in
this tunnel (average)?
30. What was the longest duration of the fire?
No occurrence (Skip questions 918)--1
Vägverket: Sweden--20 min
Happened once in lifetime--0
Korea Expressway Corporation (280 tunnels):
Less than one every year--2
South Korea--120 min
From 1 to 2 every year--2
Korea Expressway Corporation (1 tunnel): South
From 2 to 5 every year--0
Korea--25 min
Happens at least once a month--0
Ministère des transports du Québec (1 tunnel,
24. What were the most severe vehicle fire incidents in 2 bores): Canada--30 min
this tunnel? (Please check all that apply.) Sydney Harbour Tunnel Company: Australia--
Motorcycles fire--0 10 min
Passenger car fire--2
Multiple passenger cars (24 vehicles)--0 31. Have you videotaped any car fire incidence?
Vans--0 Vägverket: Sweden--No
Bus--0 Korea Expressway Corporation (280 tunnels):
Heavy goods truck fire--3 South Korea--Yes
Multiple trucks fire--0 Korea Expressway Corporation (1 tunnel): South
Tanker fire--0 Korea--Yes
Alternative fuel vehicle--0 Ministère des transports du Québec (1 tunnel,
Other--0 2 bores): Canada--Yes
Sydney Harbour Tunnel Company: Australia--Yes
25. Was there any damage made to this tunnel as a
result of the fire incident? 32. Can you share the video information?
No damages. No impact on tunnel operation--0
No damages. Tunnel was closed for operation for 30 33. Has your agency been successful in managing the
min or more--1 fire event? (Please provide an explanation.)
Minor damages (no structural damage)--3 No--0
Structural damage which required tunnel closure for Yes--5
an extended period of time--1 Partially--0
26. Were there any casualties from the fire? 34. Do you have an emergency response plan in place?
None--4 Yes--6
Minor--0
Major--1 35. Please explain what are the strengths of your
agency's fire management program?
27. Has the fire department ever been involved in Korea Expressway Corporation (280 tunnels):
fire fighting in this tunnel? South Korea
Never--0 1. Manualized procedure
Occasionally--1 2. Skilled with fire drill
Every time--4 3. Feedback from design and construction
OCR for page 137
146
Korea Expressway Corporation (1 tunnel): South Standpipe system with fire hose connections
Korea-- (dry or wet)--2
1. Manualized procedure Fire extinguishers in the tunnel--6
2. Skilled with fire drill Fire sprinkler system--3
3. Feedback from design and construction Foam system--1
Ministère des transports du Québec (1 tunnel, Fire apparatus in the tunnel--1
2 bores): Canada--Frequent fire simulation and
proximity of firefighters 40. What kind of fire life safety system does this
Sydney Harbour Tunnel Company: Australia-- tunnel have? (Please check all that apply.)
Immediate use of a deluge system if required Tunnel ventilation--7
Emergency egress--6
36. What barriers or difficulties have you or your Egress pressurization--3
organization encountered in implementing fire Other (Please explain)--2
management? (Please check all that apply.)
Technical (please explain)--0 41. What communication systems are used by rescue
Political (please explain)--1 personnel and others for fire emergency?
Legal (please explain)--0 Swedish Road Administration: Sweden--
Organizational/institutional (please explain)--1 Emergency phones and loudspeakers
Staffing/resources (please explain)--1 Vägverket: Sweden--Radio and cell phones
Other (please explain)--0 Mak Hungary: Hungary--Wall telephones every
None--2 100 m
Korea Expressway Corporation (280 tunnels):
37. What are your suggestions on how these barriers South Korea--Radio repeater
can be overcome? Korea Expressway Corporation (1 tunnel):
Mak Hungary: Hungary--We installed fire detec- South Korea--Radio repeater
tion in the new tunnels with direct lines to the Ministère des transports du Québec (1 tunnel, 2 bores):
Fire Brigade and installed fire hydrants every Canada--Radio
100 m. Sydney Harbour Tunnel Company: Australia--
Korea Expressway Corporation (1 tunnel): South Radio and fire phones
Korea--
Monitoring HGVs 42. Please explain how quickly your agency is able to
Vehicle maintenance detect and clear routine traffic crashes inside this
Installing smoke extraction tunnel?
Escape route Swedish Road Administration: Sweden--Our
Ministère des transports du Québec (1 tunnel, 2 bores): CCTV detects stopped vehicle in 30 seconds and
Canada--Frequent training and debriefing. our assistance car or fire department are on place
Sydney Harbour Tunnel Company: Australia-- in 10 minutes
Blunt meetings Vägverket: Sweden--Detect in minutes. Cleared in
30 min or 60 if there are injuries
Mak Hungary: Hungary--2 min
Section 4 Fire Detection, Fire Protection,
Communication Korea Expressway Corporation (280 tunnels): South
Korea--Detect in 2.2 min and clear in 54 min
38. What kind of fire detection system does the tunnel Korea Expressway Corporation (1 tunnel): South
have? (Please check all that applies.) Korea--Average detection time: 2.2 min
Heat Detection (linear)--5 Average time to arrive at site: 8.7 min
Heat Detection (other than linear)--2 Ministère des transports du Québec (1 tunnel,
Smoke Detection--3 2 bores): Canada--15 min
Pull Station--0 Sydney Harbour Tunnel Company: Australia--
CCTV--6 within 10 min
Video surveillance technology--3
Phones--7 43. Do you have tow trucks in your agency or do you
Other (Please explain)--4 contract out for theses services?
39. What kind of fire protection system does the Have tow trucks--0
tunnel have? (Please check all that apply.) Contract out for tow trucks--6
Fire Hydrants along the tunnel--5 Other (Please explain)--0
OCR for page 137
147
44. Are you concerned that your tunnel may not 50. Do you apply a risk assessment approach for fire
have an adequate fire/life safety system to engineering?
manage a significant fire event? Please Yes--7
explain. No--0
Vägverket: Sweden--The problem is with congested Other (Please explain)--0
traffic. The fire safety design is based on a fire
flow traffic, which travels faster than the smoke. 51. How do you handle specific risk that cannot be
When there's risk of congestion, the tunnel entry mitigated?
will shut down. Vägverket: Sweden--Improve the safety measures,
Korea Expressway Corporation (280 tunnels): South such as distance between exits, FFFS, traffic
Korea--Little concern with hardware. Software control, etc.
and skilled staff in charge is more important. Korea Expressway Corporation (280 tunnels): South
Sydney Harbour Tunnel Company: Australia--No Korea--Main goal is to minimize specific risk
such as chemical tanker leak or explosive material.
Korea Expressway Corporation (1 tunnel): South
Section 5 Design Korea--Main goal is to minimize specific risk
such as chemical tanker leak or explosive material.
45. Does your agency have their own standard for Ministère des transports du Québec (1 tunnel,
tunnel design and for Fire Rating? 2 bores): Canada--When we can we eliminate
Yes--4 the risk at the source; otherwise, we try to miti-
No--3 gate by being prepared to intervene optimally.
Other (Please explain)--0 Sydney Harbour Tunnel Company: Australia--
Vigilance
46. What guidance and standards are provided to
designers to address the fire design issues for 52. What traffic management and safety innovations
new and for retrofitted tunnels? (Please check all are deployed or planned to minimize or eliminate
that apply.) problems such as congestion and traffic manage-
NFPA 502--1 ment during a fire?
ASHRAE--0 Vägverket: Sweden--The tunnel entrances are shut
FHWA--0 automatically, ramp metering are reducing traffic
Other (Please explain)--5 (Tunnel04, European at the surface to let the cars leave the tunnel as
Union, domestic regulation, PIARC) quickly as possible.
Korea Expressway Corporation (280 tunnels): South
47. Do you specify the design fire size and fire Korea--Entrance shut equipment, Lane control
curve to the designers? (Please check all that system, Variable messaging sign by Patrol per-
apply.) sonnel Korea Expressway Corporation (1 tunnel):
Fire Size--4 South Korea--Entrance suspension equipment,
Fire Curve--3 Lane control system, Variable messaging sign
Required to follow the NFPA 502--1 control by patrol car
Leave it up to the Consultant--2 Ministère des transports du Québec (1 tunnel,
Leave it up to the Authority Having Jurisdiction 2 bores): Canada--ITS, detection, and
(AHJ)--2 communications equipment
Other (Please explain)--1 (Risk Analysis) Sydney Harbour Tunnel Company: Australia--
Vigilance Waterscreen displaying a 7 × 4.5 m
48. Is security blast design included in the require- stop sign
ments? (Please check all that apply.)
Security--2 53. Do you have an emergency response plan in place?
Blast Design--1 Yes--5
Security and Blast Design--2 No--0
Other (Please explain)--2
49. Who is the Authority Having Jurisdiction
(AHJ)? 54. Which agency has the role of incident commander?
Our agency--1 Vägverket: Sweden--fire brigade
Fire department--3 Mak Hungary: Hungary--fire brigade
Don't know--0 Korea Expressway Corporation (280 tunnels): South
Other (Please explain)--2 Korea--In cooperation with fire department
OCR for page 137
148
Korea Expressway Corporation (1 tunnel): South 60. What is this tunnel life's expectancy?
Korea--In cooperation with fire department Swedish Road Administration--80 years
Ministère des transports du Québec (1 tunnel, Vägverket: Sweden--100 years
2 bores): Canada--Firefighters Mak Hungary: Hungary--200 years
Sydney Harbour Tunnel Company: Australia--Fire Korea Expressway Corporation (280 tunnels):
brigade once on site South Korea--50 to 100 years
Korea Expressway Corporation (1 tunnel): South
55. What best practices can you share in the areas of Korea--50 to 100 years
prevention, mitigation, and recovery from fire Ministère des transports du Québec (1 tunnel,
incidence? 2 bores): Canada--100 years
Korea Expressway Corporation (280 tunnels): South Sydney Harbour Tunnel Company: Australia--
Korea--From the case of Dalsung Tunnel acci- 100 years
dent, which is explosion of missile propellant.
Korea Expressway Corporation (1 tunnel): South 61. Do you have any additional suggestions and
Korea--Explosion of missile projectile case in thoughts on the design for fire emergency?
Dalsung Tunnel Vägverket: Sweden--There are 100 m between
>20 hours to re-open the emergency exits. The fire brigade can use
>3 month to full recovery these to reach an accident and never have to take
Sydney Harbour Tunnel Company: Australia--
the risk of entering the burning tunnel with their
Video smoke detection.
vehicles.
Alert operators
Korea Expressway Corporation (1 tunnel): South
Deluge system
Korea--Equipping extinguisher and respirator
should be forced by law
56. Would you consider protection of the tunnel
with the fixed fire suppression system (sprinkler
system) to meet the new NFPA 502 Max Fire 62. Please identify any research that you would like
Heat Release Rate Requirements, if proven to see performed to help in the implementation of
effective? fire safety systems.
Yes--4 Vägverket: Sweden--More research to develop the
No--2 installations in a more cost-effective way
Other (Please explain)--0
57. Have you identified gaps in research and Section 6 Operation, Maintenance, Repair,
Rehabilitation
design for tunnel fire safety, or fire detection
and protection?
63. What types of exercises and other training are
No--2
provided to staff and first responders to ensure
Yes (Please explain)--4
proficiency in response to an incident and how is
the training evaluated?
58. Can you suggest strategies to eliminate the gaps
Vägverket: Sweden--The staff of the traffic com-
and improve tunnel fire safety?
mand centre have annual exercises to handle a
Vägverket: Sweden--More research to develop the
installations in a more cost-effective way large accident. The personnel in the incident
Korea Expressway Corporation (1 tunnel): South response vehicles have a full fire fighter training
Korea-- and annual exercises.
Promotion (PR) Korea Expressway Corporation (1 tunnel): South
Accident prevention Korea--Annual fire drill with fire department by
Improvement of facilities manual, technical education, spot check, real fire
Sydney Harbour Tunnel Company: Australia-- case evaluation
Closer ties to other operators Ministère des transports du Québec (1 tunnel,
2 bores): Canada--Ventilation test with fire and
59. Would you consider a fire event to be similar to a smoke
seismic event for design purposes? (Example Sydney Harbour Tunnel Company: Australia--
design for the fire event which has a high probabil- We burn cars in the tunnel to demonstrate the
ity to happen once in 500 years or 2,500 years?) smoke, heat, and noise to our operators. This
Yes--0 also enables the deluge and ventilation to be
No--5 proven. All operators have to complete task
Other (Please explain)--1 books on a regular basis.
OCR for page 137
149
64. Would you need additional training tools for Sydney Harbour Tunnel Company: Australia--
operators to manage a fire? Consultants
Tunnel Fire/Systems Simulator--4
No--2 69. If you were to start a new tunnel project, what
Other (please explain)--1 key elements would you incorporate in the
design and construction to aid you in tunnel fire
65. What equipment and materials are pre-positioned incident management?
for response and recovery to a fire, such as for Vägverket: Sweden--Traffic control on the
the quick removal of disabled vehicles? surface around the tunnel, to insure that
Vägverket: Sweden--The incident response vehi- the traffic can get out of the tunnel system
cles are positioned so that they can reach any part quickly.
of the tunnel system within 5 minutes 24-7. The Korea Expressway Corporation (1 tunnel): South
tow trucks have a quick response time. Korea--smoke extraction in combination with
Mak Hungary: Hungary--The fire brigade has their ventilation FFFS
own container full of rescue equipment Sydney Harbour Tunnel Company: Australia--
Korea Expressway Corporation (1 tunnel): South Deluge and clear identification of deluge
Korea--Special equipment to tow for special zones
trucks
Ministère des transports du Québec (1 tunnel, 2 bores): 70. Are the lighting and emergency communication
Canada--Towing trucks system designed to survive major fire events?
Sydney Harbour Tunnel Company: Australia--Two Yes--5
tow trucks during peak periods No (please explain how to ensure safe evacuation
during an incident that involves major fires)--1
66. What is considered an acceptable response time? Other (Please explain)--0
Swedish Road Administration--10 min
Vägverket: Sweden--5 min 71. What are the operational protocols for the
Korea Expressway Corporation (280 tunnels): use of the ventilation system during a fire
South Korea--10 to 15 min event?
Korea Expressway Corporation (1 tunnel): South Vägverket: Sweden--Yes, the ventilation is very
Korea--10 to 15 min important in case of a fire.
Ministère des transports du Québec (1 tunnel, 2 bores): Mak Hungary: Hungary--Manual
Canada--7 min Korea Expressway Corporation (1 tunnel): South
Sydney Harbour Tunnel Company: Australia--Less Korea--Keep critical velocity after completion of
than 2 min evacuation downstream of fire
Ministère des transports du Québec (1 tunnel,
67. How often are tunnels and emergency response 2 bores): Canada--Preprogrammed scenarios are
equipment inspected and tested? operated and depend on the fire location, with
Swedish Road Administration--Depends regard to the camera seeing the fire
Vägverket: Sweden--Annually Sydney Harbour Tunnel Company: Australia--
Korea Expressway Corporation (280 tunnels): Preprogrammed for single fire, multiple fire, and
South Korea--At least once a month congested tunnel.
Korea Expressway Corporation (1 tunnel): South
Korea--At least once a month 72. How are the maintenance considerations
Ministère des transports du Québec (1 tunnel, worked into the design elements of tunnel fire
2 bores): Canada--2 times a year detection and fire suppression systems?
Sydney Harbour Tunnel Company: Australia-- Vägverket: Sweden--No key parts in the traffic
Every 6 months tunnel, as much maintenance as possible should
be carried out in technical rooms and emergency
68. What methods are used to inspect the structural exits.
integrity of the tunnel structure both routinely Korea Expressway Corporation (1 tunnel): South
and after a fire? What materials are used to Korea--Every result of maintenance, fire drill, and
repair concrete after a fire? fire accident are considered into design. For
Vägverket: Sweden--The road authority provides example, corrosion problems of metals in the
specialists after an incident. There are maintenance tunnel, false alarm of FFFS, etc.
done in the tunnels every month, and the tunnel Sydney Harbour Tunnel Company: Australia--
structures are checked after a time schedule. Video smoke detection does not require access
OCR for page 137
150
to the tunnel. Cameras must be located at about 75. What systems do you have plans for repair or
60 m intervals replacement of fire or life safety equipment?
(Please check all that apply.)
73. Do you actively screen or otherwise monitor truck Tunnel ventilation--0
cargoes entering the tunnel without disrupting the Fire suppression--0
traffic flow? Standpipes--1
Yes--1 Fire detection--0
No--5 Communication--0
Other (Please explain)--0 Emergency lighting--0
Other (Please explain)--0
74. What dangerous cargo is acceptable and how is
this enforced?
Vägverket: Sweden--All types of cargo at night, no Section 7 Follow-up
explosive cargo at daytime.
Korea Expressway Corporation (280 tunnels): 76. Please provide any additional information or
South Korea--No restriction suggestions you may have.
Korea Expressway Corporation (1 tunnel): South Sydney Harbour Tunnel Company: Australia--
Korea--No restriction of material. Only loading Provide good training to good operators with the
method is restricted. right tools to do the job
Ministère des transports du Québec (1 tunnel, 2 bores):
Canada-- The last two questions were used so that the researchers
Sydney Harbour Tunnel Company: Australia-- could contact the respondent for additional information, if
None, government agency responsibility necessary.