Prudent Practices in the Laboratory: Handling and Disposal of Chemicals
Reactivity and Incompatibility
Pyridine may react violently with dinitrogen tetroxide, acid chlorides and anhydrides, perchloric acid, and strong oxidizing agents.
Storage and Handling
Pyridine should be handled in the laboratory using the "basic prudent practices" described in Chapter 5.C. In particular, pyridine should be used only in areas free of ignition sources, and quantities greater than 1 liter should be stored in tightly sealed metal containers in areas separate from oxidizers.
Accidents
In the event of skin contact, immediately wash with soap and water and remove contaminated clothing. In case of eye contact, promptly wash with copious amounts of water for 15 min (lifting upper and lower lids occasionally) and obtain medical attention. If pyridine is ingested, obtain medical attention immediately. If large amounts of this compound are inhaled, move the person to fresh air and seek medical attention at once.
In the event of a spill, remove all ignition sources, soak up the pyridine with a spill pillow or absorbent material, place in an appropriate container, and dispose of properly. Respiratory protection may be necessary in the event of a large spill or release in a confined area.
Disposal
Excess pyridine and waste material containing this substance should be placed in an appropriate container, clearly labeled, and handled according to your institution's waste disposal guidelines. For more information on disposal procedures, see Chapter 7 of this volume.