Linking the Construction Industry: Electronic Operation and Maintenance Manuals: Workshop Summary (2000)
Federal Facilities Council (FFC)

Page
34
bottomleft bottomright

The following HTML text is provided to enhance online readability. Many aspects of typography translate only awkwardly to HTML. Please use the page image as the authoritative form to ensure accuracy.


Linking the Construction Industry: Electronic Operation and Maintenance Manuals

APPENDIX C

Document Type Definition Document

Page
34

Below are the first 10 and last 10 pages of uncorrected machine-read text (when available) of this chapter, followed by the top 30 algorithmically extracted key phrases from the chapter as a whole.
Intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text on the opening pages of each chapter. Because it is UNCORRECTED material, please consider the following text as a useful but insufficient proxy for the authoritative book pages.

Do not use for reproduction, copying, pasting, or reading; exclusively for search engines.

OCR for page 34
Linking the Construction Industry: Electronic Operation and Maintenance Manuals APPENDIX C Document Type Definition Document

OCR for page 35
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- The formal public identifier for the following set of declarations comprising the “docomsi” DTD is: <!DOCTYPE docomsi PUBLIC “-//USA-DOD//DTD FOR FACILITIES OPERATION AND MAINTENANCE MANUALS 980309//EN”> --> <!-- To parse the “docomsi” DTD, place “<!DOCTYPE docomsi [“ at the beginning of this file and ”]>” at the end of this file. --> <!-- This document type definition (DTD) models the documents proposed to implement the Operation and Maintenance Support Information (OMSI) concept initiated by the Naval Facilities Engineering Command (NAVFACENGCOM) and the Public Health Service to improve the operation and maintenance of facilities. This DTD is based on: (1) an analysis and modelling of the of the seven volume sample document “Building 1579 Bachelor Enlisted Quarters Norfolk Naval Shipyard”; (2) some King's Bay material; and (3) information/guidance provided by NAVFACENGCOM. Also certain commonly used CALS SGML constructs (element, attribute, entity definitions, etc.) from tables I and II of MIL-PRF-28001B (the CALS SGML performance specification) were used as appropriate to complete the modelling. For further information concerning the OMSI concept or the availability of this DTD (which is in the preliminary draft stage) contact either: Dr. William Brodt 301-496-4941 brodtb@des13.od.nih.gov FAX: 301-402-7182 Mr. Eric Jackson 757-322-4616 jacksonea@edflant.navfac.navy.mil FAX: 757-322-4614 This DTD was written for NAVFACENGCOM by the Technology Implementation Support Team of the Naval Surface Warfare Center, Carderock Division. For information regarding this DTD, contact either: Ms. Lori Westbrook 301-227-3346 westbroo@dt.navy.mil Mr. Donald Gignac 301-227-3348 gignac@dt.navy.mil of the Technology Implementation Support Team (NSWCCD Code 2053) Naval Surface Warfare Center Carderock Division 9500 MacArthur Boulevard West Bethesda, MD 20817-5700. whose FAX number is 301-227-3343. --> <!-- START OF DOCOMSI DTD --> <!-- COMMONLY USED CALS PARAMETER ENTITIES --> <!-- TEXT COMPONENTS --> <!ENTITY % text “(#PCDATA | subscrpt | supscrpt | emphasis | xref | graphic | extref)+ ”>

OCR for page 36
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- LIST OPTIONS --> <!ENTITY % list “seqlist | deflist | randlist”> <!-- PARAGRAPH CONTENT --> <!ENTITY % paracon “paratext | %list;”> <!-- YES OR NO ATTRIBUTE VALUE --> <!ENTITY % yesorno “NUMBER”> <!-- END OF COMMONLY USED CALS PARAMETER ENTITIES --> <!-- OMSINFO: OPERATIONS MAINTENANCE & SUPPORT INFORMATION --> <!ELEMENT docomsi - - (facinfo, sysinfo, proddata)> <!-- FACINFO: FACILITY INFORMATION --> <!ELEMENT facinfo - - (preface, mtoc, genfac-sysdes, basdes, safhaz, flplans, utilplans, extwarinfo, equipinvent, hvacfilts, flcovers, wallcovers, ceilsurfs, windows, ltfixts, plumbfixts, roofing, supinvreqs, man-supp-contract?, abdrawlist, trainreqs, skillmatrix) +(table | graphic)> <!-- PREFACE: PREFACE --> <!ELEMENT preface - - (para0+) - (table | graphic)> <!-- MTOC: AUTOMATICALLY GENERATED MASTER TABLE OF CONTENTS --> <!ELEMENT mtoc - O EMPTY> <!-- GENFAC-SYSDES: GENERAL FACILITY & SYSTEM DESCRIPTION --> <!ELEMENT genfac-sysdes - - (facdes, syst+)> <!-- FACDES: FACILITY DESCRIPTION --> <!ELEMENT facdes - - (para0+)> <!-- SYST: NAME OF FACILITY SYSTEM --> <!ELEMENT syst - - (title, para0+)> <!-- “idref” on “sys” links to “id” on corresponding system --> <!ATTLIST syst idref IDREF #IMPLIED> <!-- BASDES: BASIS OF DESIGN --> <!ELEMENT basdes - - (para0+)> <!-- SAFHAZ: SAFETY HAZARDS --> <!ELEMENT safhaz - - (para0+)> <!-- FLPLANS: FLOOR PLANS UTILPLANS: UTILITY CONNECTION AND CUTOFF PLANS --> <!ELEMENT (flplans | utilplans) - - (para0 | table | graphic)*> <!-- EXTWARINFO: COLLECTION OF EXTENDED WARRANTY INFORMATION --> <!ELEMENT extwarinfo - - (para0*, extwarrant*)> <!-- EXTWARRANT: EXTENDED WARRANTY INFORMATION --> <!ELEMENT extwarrant - -(extwarrantline)+>

OCR for page 37
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- EXTWARRANTLINE: LINE OF EXTENDED WARRANTY INFORMATION --> <!ELEMENT extwarrantline - -(title, specsect, duration, startdate, enddate, poc)> <!--SPECSECT: RELEVANT SPECIFICATION SECTION DURATION: DURATION OF WARRANTY STARTDATE: START DATE OF WARRANTY ENDDATE: END DATE OF WARRANTY --> <!ELEMENT (specsect | duration | startdate | enddate) - - (#PCDATA) > <!-- POC: POINT OF CONTACT --> <!ELEMENT poc - - (mfr | supplier | contractor | subcontractor | installer) > <!-- WINDOWS: WINDOWS HVACFILTS: HVAC FILTERS FLCOVERS: FLOOR COVERINGS WALLCOVERS: WALL COVERINGS CEILSURFS: CEILING SURFACES --> <!ELEMENT (windows | hvacfilts | flcovers | wallcovers | ceilsurfs) - - (para0*)> <!-- ROOFING: ROOFING --> <!ELEMENT roofing - - (para0*, poc?, contractor?, subcontractor?, installer?)> <!-- EQUIPINVENT: EQUIPMENT INVENTORY - CONTENT MODEL --> <!ELEMENT equipinvent - - (equip*)> <!-- EQUIP: PIECE OF EQUIPMENT --> <!ELEMENT equip - - (title, equipline+)> <!-- EQUIPLINE: LINE OF EQUIPMENT INFORMATION --> <!ELEMENT equipline - -(equipdes, location?, modelno, tagno?, serno?, mfr?, supplier?)> <!-- TAGNO: TAG NUMBER SERNO: SERIAL NUMBER --> <!ELEMENT (tagno | serno) - - CDATA> <!-- EQUIPDES: EQUIPMENT DESCRIPTION LOCATION: LOCATION MODELNO: MODEL NUMBER (CALS) PARTNO: PART NUMBER (CALS) --> <!ELEMENT (equipdes | location | modelno | partno) - - (%text;)> <!ATTLIST (modelno | partno) label CDATA #IMPLIED id ID #IMPLIED idref IDREF #IMPLIED> <!--MFR: MANUFACTURE (CALS) SUPPLIER: SUPPLIER --> <!ELEMENT (mfr | supplier | contractor | subcontractor | installer) - - (name, address, phone)>

OCR for page 38
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!ATTLIST (mfr | supplier | contractor | subcontractor | installer) label CDATA #IMPLIED id ID #IMPLIED idref IDREF #IMPLIED> <!-- NAME: NAME ADDRESS: ADDRESS PHONENO: PHONE NUMBER --> <!ELEMENT (name | address | phone) - - (%text;)> <!--LTFIXTS: LIGHTING FIXTURES PLUMBFIXTS: PLUMBING FIXTURES --> <!ELEMENT (ltfixts | plumbfixts) - - (para0*)> <!-- SUPINVREQS: SUPPLY INVENTORY REQUIREMENTS --> <!ELEMENT supinvreqs - - (trade*)> <!-- TRADE: TRADE --> <!ELEMENT trade - - (title, (partdes, partno, qty, equipusedon, name, address, phone)+)> <!-- EQUIPUSEDON: EQUIPMENT USED ON --> <!ELEMENT equipusedon - - (seqlist?)> <!-- MAN-SUPP-CONTRACT: MANUFACTURERS, SUPPLIERS, AND CONTRACTORS/SUBCONTRACTORS --> <!ELEMENT man-supp-contract - - (para0+)> <!-- ABDRAWLIST: AS-BUILT DRAWING LIST --> <!ELEMENT abdrawlist - - (para0*, table*)> <!-- TRAINREQS: TRAINING REQUIREMENTS --> <!ELEMENT trainreqs - - (title, reqtrain, oprec?)> <!ATTLIST trainreqs system IDREFS #REQUIRED> <!-- REQTRAIN: REQUIRED TRAINING --> <!ELEMENT reqtrain - - (mfr, descrip+)+> <!-- DESCRIP: TRAINING DESCRIPTION OPRECS: OPTIONAL RECOMMENDATIONS --> <!ELEMENT (descrip | oprec) - - (para0+)> <!-- SKILLMATRIX: SKILL MATRIX --> <!ELEMENT skillmatrix - - (para0*, table)> <!-- SYSINFO: PRIMARY SYSTEMS INFORMATION --> <!ELEMENT sysinfo - - (system+) +(table | graphic)> <!-- SYSTEM: SYSTEM --> <!ELEMENT system - - (operation, prevmaint, repair, man-data) +(warning | caution | note)> <!-- “id” links to “idref” on corresponding “syst” --> <!ATTLIST system id ID #REQUIRED>

OCR for page 39
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- OPERATION: OPERATION --> <!ELEMENT operation - - (sysdes, start-shut, normal, flowdia, diaplan, emergency, environment, fieldtestreps?, opservreq, safeinst, valvelist, oplog, calprocs?)> <!-- SYSDES: SYSTEM DESCRIPTION --> <!ELEMENT sysdes - - (para0+)> <!-- START-SHUT: START-UP AND SHUTDOWN PROCEDURES --> <!ELEMENT start-shut - - (para0*, start-up, shutdown)+> <!--START-UP: START-UP PROCEDURES SHUTDOWN: SHUTDOWN PROCEDURES --> <!ELEMENT (start-up | shutdown) - - (para0*, step1+)> <!-- NORMAL: NORMAL OPERATING INSTRUCTIONS --> <!ELEMENT normal - - (para0+)> <!-- FLOWDIA: SYSTEM FLOW DIAGRAMS DIAPLAN: DIAGRAMMATIC PLANS --> <!ELEMENT (flowdia | diaplan) - - (para0*, graphic+)> <!-- EMERGENCY: EMERGENCY OPERATING INSTRUCTIONS --> <!ELEMENT emergency - - (para0*, step1*)> <!-- FIELDTESTREP: FIELD TEST REPORT ENVIRONMENT: ENVIROMENTAL CONSIDERATIONS OPSERVREQ: OPERATOR SERVICING REQUIREMENTS SAFEINST: SAFETY INSTRUCTIONS --> <!ELEMENT (fieldtestreps | environment | opservreq | safeinst) - -(para0+)> <!-- VALVELIST: VALVE LIST --> <!ELEMENT valvelist - - (para0*, (table | graphic)* )> <!-- OPLOG: OPERATING LOGS --> <!ELEMENT oplog - - (para0, graphic+)+> <!-- CALPROCS: CALIBRATION PROCEDURES --> <!-- ELEMENT calprocs - - (para0, step1*)+> <!-- PREVMAINT: PREVENTIVE MAINTENANCE PROCEDURES --> <!ELEMENT prevmaint - - (plan-sched, pmproc, pmlog, lube)> <!-- PLAN-SCHED: PREVENTIVE MAINTENANCE PLAN & SCHEDULE --> <!ELEMENT plan-sched - - (para0 | graphic)+> <!-- PMPROC: PREVENTIVE MAINTENANCE PROCEDURES --> <!ELEMENT pmproc - - (para0*, taskcard+)> <!-- INTRO: INTRODUCTION TO PREVENTATIVE MAINTENANCE PROCEDURES --> <!ELEMENT intro - - (para0+)> <!-- TASKCARD: WORK ORDER TASK CARD --> <!ELEMENT taskcard - - (graphic)>

OCR for page 40
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!ATTLIST taskcard system CDATA #REQUIRED> <!-- PMLOG: PREVENTIVE MAINTENANCE LOG LUBE: LUBRICATION SCHEDULE --> <!ELEMENT (pmlog | lube) - - (para0*, graphic*)> <!-- REPAIR: REPAIR --> <!ELEMENT repair - - (ts-diag, rproc, rem-rep, rlog)> <!--TS-DIAG: TROUBLESHOOTING & DIAGNOSTICS RPROC: REPAIR PROCEDURES REM-REP: REMOVAL & REPLACEMENT INSTRUCTIONS --> <!ELEMENT (ts-diag | rproc | rem-rep) - - (para0+, (table | graphic)*) > <!-- RLOG: REPAIR LOG --> <!ELEMENT rlog - - (para0+)> <!-- MAN-DATA: MANUFACTURER'S DATA --> <!ELEMENT man-data - - (mdop-maint, meqinfo)> <!-- MDOP-MAINT: MANUFACTURER'S OPERATING AND MAINTENANCE DATA MEQINFO: MANUFACTURER'S EQUIPMENT INFORMATION --> <!ELEMENT (mdop-maint | meqinfo) - - (para0?, graphic)+> <!-- PRODDATA: PRODUCT DATA --> <!ELEMENT proddata - - (sectinfo+)> <!-- SECTINFO: CSI MASTERFORMAT SECTION NUMBER --> <!ELEMENT sectinfo - - (prodinfo*)> <!-- label required to provide “02000 - SITE WORK” (for example) --> <!ATTLIST sectinfo label CDATA #REQUIRED -- “reserved” allows for “This section reserved for future use.” remember this is a deprecated practice -- reserved (yes) #CONREF> <!-- PRODINFO: PRODUCT INFORMATION --> <!ELEMENT prodinfo - - (title?, cutsheet*, mdop-maint?, warranty*) > <!-- CUTSHEET: PRODUCT SHEETS/SPECIFICATIONS --> <!ELEMENT cutsheet - - (partdes, name, modelno, partno, qty, unit, measure, tools, partlist, applicabil) +(graphic)> <!-- MEASURE: MEASUREMENT SYSTEM --> <!ELEMENT measure - - (impmeas*, simeas*)> <!-- IMPMEAS: IMPERIAL MEASURE SIMEAS: SI MEASURE --> <!ELEMENT (impmeas | simeas) - - (unit, qty)> <!-- UNIT: UNIT QTY: QUANTITY --> <!ELEMENT (unit | qty) - - (#PCDATA)>

OCR for page 41
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- TOOLS: TOOLS --> <!ELEMENT tools - - (para0*)> <!-- APPLICABIL: APPLICABILITY --> <!ELEMENT applicabil - - (partdes, name, modelno, partno)*> <!-- PARTLIST: PART LIST --> <!ELEMENT partlist - - (%list;)+> <!-- WARRANTY: WARRANTY INFORMATION --> <!ELEMENT warranty - -(partdes, title, modelno, partno) +(graphic) > <!ATTLIST warranty type (system | component) #IMPLIED> <!-- PARTDES: PART DESCRIPTION --> <!ELEMENT partdes - - (para0 | graphic | %list;)*> <!-- BASIC CALS ELEMENTS --> <!-- Primary Paragraph --> <!ELEMENT para0 - - (title?, para+, subpara1*)> <!ATTLIST para0 id ID #IMPLIED label CDATA #IMPLIED> <!-- Paragraph Text (Must Not Contain Lists) --> <!ELEMENT paratext - - (%text;)+> <!-- Untitled Paragraph (Contains Paragraph Text and/or Lists) --> <!ELEMENT para - - (paratext | %list; | table)+> <!-- First Order Subparagraph --> <!ELEMENT subpara1 - - (title?, para+)> <!-- First Order Procedural Step --> <!ELEMENT step1 - - ((para | warning | caution | note)+, step2*)> <!-- Second Order Procedural Step --> <!ELEMENT step2 - - ((para | warning | caution | note)+, step3*)> <!-- Third Order Procedural Step --> <!ELEMENT step3 - - ((para | warning | caution | note)+, step4*)> <!-- Fourth Order Procedural Step --> <!ELEMENT step4 - - ((para | warning | caution | note)+, step5*)> <!-- Fifth Order Procedural Step --> <!ELEMENT step5 - - ((para | warning | caution | note)+, step6*)> <!-- Sixth Order Procedural Step --> <!ELEMENT step6 - - ((para | warning | caution | note)+, step7*)> <!-- Seventh Order Procedural Step --> <!ELEMENT step7 - - (para | warning | caution | note)+>

OCR for page 42
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- Cross-Reference within a Document --> <!ELEMENT xref - O EMPTY> <!ATTLIST xref xrefid IDREF #REQUIRED xidtype (figure | table | text) #REQUIRED pretext CDATA #IMPLIED posttext CDATA #IMPLIED> <!-- Reference of an External Document --> <!ELEMENT extref - o EMPTY > <!ATTLIST extref docno CDATA #IMPLIED pretext CDATA #IMPLIED posttext CDATA #IMPLIED> <!-- Special Paragraph Text: Warning / Caution / Note --> <!ELEMENT (warning | caution | note) - - (%paracon; | table)+> <!ATTLIST (warning | caution) id ID #IMPLIED idref IDREF #IMPLIED label CDATA #IMPLIED xlink CDATA #IMPLIED> <!ATTLIST note id ID #IMPLIED idref IDREF #IMPLIED label CDATA #IMPLIED xlink CDATA #IMPLIED prefix CDATA #IMPLIED> <!-- Generic Title --> <!ELEMENT title - - (%text;)+> <!ATTLIST title id ID #IMPLIED label CDATA #IMPLIED> <!-- Sequential List --> <!ELEMENT seqlist - - (title?, item+)> <!ATTLIST seqlist id ID #IMPLIED label CDATA #IMPLIED numstyle (none | arabic | alphalc | arabic-parens | alphalc-parens | arabic-dashes | alphalc-dashes ) #IMPLIED> <!-- Random List --> <!ELEMENT randlist - - (title?, item+)> <!ATTLIST randlist prefix CDATA #IMPLIED> <!-- Sequential \ Random List Item --> <!ELEMENT item - - (%paracon; | table | chart)+> <!ATTLIST item id ID #IMPLIED label CDATA #IMPLIED idref IDREF #IMPLIED spinno CDATA #IMPLIED> <!-- Graphic -->

OCR for page 43
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!ELEMENT graphic - o EMPTY> <!ATTLIST graphic boardno ENTITY #REQUIRED id ID #IMPLIED label CDATA #IMPLIED> <!-- Subscript / Superscript --> <!ELEMENT (subscrpt | supscrpt) - - CDATA> <!-- Definition List --> <!ELEMENT deflist - - (title?, (term, def)+)> <!-- Term To Be Defined in Definition List --> <!ELEMENT term - - (%text;)+> <!-- Definition of Term in Definition List --> <!ELEMENT def - - (%paracon; | table)+> <!-- Emphasis --> <!ELEMENT emphasis - - (%text;)+> <!ATTLIST emphasis type (bold | underline) #REQUIRED> <!-- CALS Table Model (Modified to Allow Title Above or Below) --> <!ELEMENT (table | chart) - - ((title, tgroup+) | (tgroup+, title?)) -(table | chart)> <!ATTLIST (table | chart) frame (top | bottom | topbot | all | sides | none) #IMPLIED colsep %yesorno; #IMPLIED rowsep %yesorno; #IMPLIED orient (port | land) #IMPLIED pgwide %yesorno; #IMPLIED id ID #IMPLIED calltable %yesorno; #IMPLIED> <!-- Table Group --> <!ELEMENT tgroup - o (colspec*, spanspec*, thead?, tfoot?, tbody) > <!ATTLIST tgroup cols NUMBER #REQUIRED colsep %yesorno; #IMPLIED rowsep %yesorno; #IMPLIED align (left | right | center | justify | char) “left” charoff NUTOKEN “50” char CDATA “ ”> <!-- Column Specification --> <!ELEMENT colspec - o EMPTY> <!ATTLIST colspec colnum NUMBER #IMPLIED colname NMTOKEN #IMPLIED align (left | right | center | justify | char) #IMPLIED charoff NUTOKEN #IMPLIED char CDATA #IMPLIED colwidth CDATA #IMPLIED colsep %yesorno; #IMPLIED rowsep %yesorno; #IMPLIED> <!-- Span Specification -->

OCR for page 44
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!ELEMENT spanspec - o EMPTY > <!ATTLIST spanspec namest NMTOKEN #REQUIRED nameend NMTOKEN #REQUIRED spanname NMTOKEN #REQUIRED align (left | right | center | justify | char) “center” charoff NUTOKEN #IMPLIED char CDATA #IMPLIED colsep %yesorno; #IMPLIED rowsep %yesorno; #IMPLIED> <!-- Table Head / Table Foot --> <!ELEMENT (thead | tfoot) - o (colspec*, row+) -(entrytbl) > <!ATTLIST thead valign (top | middle | bottom) “bottom”> <!ATTLIST tfoot valign (top | middle | bottom) “top”> <!-- Table Body --> <!ELEMENT tbody - o (row+)> <!ATTLIST tbody valign (top | middle bottom) “top”> <!-- Table Row --> <!ELEMENT row - o (entry | entrytbl)+ > <!ATTLIST row rowsep %yesorno; #IMPLIED> <!-- Table Row Entry / Component Description Box Entry --> <!ELEMENT entry - - (paratext | %list;)+> <!ATTLIST entry colname NMTOKEN #IMPLIED namest NMTOKEN #IMPLIED nameend NMTOKEN #IMPLIED spanname NMTOKEN #IMPLIED morerows NUMBER “0” colsep %yesorno; #IMPLIED rowsep %yesorno; #IMPLIED rotate %yesorno; “0” valign (top | bottom | middle) “top” align (left | right | center | justify | char) #IMPLIED charoff NUTOKEN #IMPLIED char CDATA #IMPLIED idref IDREF #IMPLIED> <!-- Entry Table --> <!ELEMENT entrytbl - - (colspec*, spanspec*, thead?, tbody)+ -(entrytbl) > <!ATTLIST entrytbl cols NUMBER #REQUIRED colname NMTOKEN #IMPLIED spanname NMTOKEN #IMPLIED colsep %yesorno; #IMPLIED rowsep %yesorno; #IMPLIED align (left | right | center | justify | char) #IMPLIED charoff NUTOKEN #IMPLIED char CDATA #IMPLIED> <!-- End of CALS Table Model --> <!-- END OF BASIC CALS ELEMENTS -->

OCR for page 45
Linking the Construction Industry: Electronic Operation and Maintenance Manuals <!-- START OF DATA CONTENT NOTATION DECLARATIONS --> <!-- Each of the following notations provides a capability for accessing and processing graphical data of a certain type. --> <!NOTATION cgmbin PUBLIC “ISO 8632/3//NOTATION CGM Binary text encoding//EN”> <!NOTATION iges PUBLIC “-//USA-DOD//NOTATION (ASME/ANSI Y14.26M-1987) Initial Graphics Exchange Specification//EN”> <!NOTATION fax PUBLIC “-//USA-DOD//NOTATION CCITT Group 4 Facsimile Type1 Untiled Raster//EN ”> <!NOTATION faxtile PUBLIC “-//USA-DOD//NOTATION CCITT Group 4 Facsimile Type 2 Tiled Raster//EN ”> <!NOTATION tif SYSTEM> <!-- END OF DATA CONTENT NOTATION DECLARATIONS --> <!-- START OF ISO CHARACTER SET DECLARATIONS --> <!-- The SDATA (system dependent) character declarations contained in these character sets enable the non-keyboard characters for the application software. They also allow SGML delimiters to be used as character data. --> <!ENTITY % ISOlat1 PUBLIC “ISO 8879:1986//ENTITIES Added Latin 1//EN”> <!ENTITY % ISOpub PUBLIC “ISO 8879:1986//ENTITIES Publishing//EN”> <!ENTITY % ISOgrk1 PUBLIC “ISO 8879:1986//ENTITIES Greek Letters//EN”> <!ENTITY % ISOgrk3 PUBLIC “ISO 8879:1986//ENTITIES Greek Symbols//EN”> <!ENTITY % ISOnum PUBLIC “ISO 8879:1986//ENTITIES Numeric and Special Graphic//EN”> <!ENTITY % ISOtech PUBLIC “ISO 8879:1986//ENTITIES General Technical//EN”> %ISOlat1; %ISOpub; %ISOgrk1; %ISOgrk3; %ISOnum; %ISOtech; <!-- END OF ISO CHARACTER SET DECLARATIONS --> <!-- TABBING CAPABILITY --> <!-- Some SGML application software does not provide a tabbing capability (i.e., the spacing obtained by pressing the TAB key). Referencing the “tab” general entity below provides a 5-space TAB. --> <!ENTITY tab “ ”> <!-- END OF DOCOMSI DTD -->

Representative terms from entire chapter:

procedural step