Below is the uncorrected machine-read text of this chapter, intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text of each book. Because it is UNCORRECTED material, please consider the following text as a useful but insufficient proxy for the authoritative book pages.
103 A p p e n d i x C Outlet Control Experimental Data Set for Traditional Projecting and Slip-Lined Inlet End Treatments (Tabular Support Data for Chapter 3) Table C-1. Circular culvert outlet control performance data: thin-wall projecting end. Run Entrance Approach Control So Q Re Hw/D ke [%] [cfs] [] [] [] 1 projecting ponded outlet 0.07 2.88 207,576 3.82 0.79 2 projecting ponded outlet 0.07 2.66 189,737 3.17 0.78 3 projecting ponded outlet 0.07 1.20 86,589 1.26 0.83 4 projecting ponded outlet 0.07 1.19 70,578 0.95 0.75 5 projecting ponded outlet -0.06 3.08 238,220 3.89 0.79 6 projecting ponded outlet -0.06 2.18 169,241 1.90 0.82 7 projecting ponded outlet -0.06 2.26 175,716 2.43 0.80 8 projecting ponded outlet -0.06 2.92 228,997 3.40 0.78 9 projecting ponded outlet -0.06 0.90 69,761 0.67 0.71 10 projecting ponded outlet -0.06 0.56 56,334 0.52 0.75 Table C-2. Slip-lined circular culvert outlet control performance data: 2-inch projecting end. Run Entrance Approach Control So Q Re Hw/D ke [%] [cfs] [] [] [] 11 2-inch projecting ponded outlet -0.06 2.87 225,178 3.65 0.75 12 2-inch projecting ponded outlet -0.06 2.83 232,482 3.06 0.77 13 2-inch projecting ponded outlet -0.06 2.65 218,633 2.50 0.76 14 2-inch projecting ponded outlet -0.06 2.40 198,100 1.94 0.78 15 2-inch projecting ponded outlet -0.06 2.13 175,176 1.49 0.78 16 2-inch projecting ponded outlet -0.06 1.59 100,877 1.01 0.71 17 2-inch projecting ponded outlet -0.06 1.17 80,539 0.79 0.66 18 2-inch projecting ponded outlet -0.06 0.53 56,514 0.50 0.68
104 Table C-3. Slip-lined circular culvert outlet control performance data: 4-inch projecting end. Run Entrance Approach Control So Q Re Hw/D ke [%] [cfs] [] [] [] 19 4-inch projecting ponded outlet 0.03 2.34 168,709 2.37 0.77 20 4-inch projecting ponded outlet 0.03 2.18 157,278 1.77 0.79 21 4-inch projecting ponded outlet 0.03 1.89 136,830 1.32 0.80 22 4-inch projecting ponded outlet 0.03 1.65 97,989 1.02 0.77 23 4-inch projecting ponded outlet 0.03 2.86 205,944 4.19 0.76 24 4-inch projecting ponded outlet 0.03 2.69 193,137 3.42 0.76 25 4-inch projecting ponded outlet 0.03 2.51 180,313 2.77 0.78 26 4-inch projecting ponded outlet 0.03 1.19 72,470 0.85 0.73 27 4-inch projecting ponded outlet 0.03 0.92 68,119 0.66 0.66 28 4-inch projecting ponded outlet 0.03 0.44 41,620 0.45 0.69 Table C-4. Slip-lined circular culvert outlet control performance data: 2-inch tapered, projecting end. Run Entrance Approach Control So Q Re Hw/D ke [%] [cfs] [] [] [] 29 2-inch tapered proj. ponded outlet -0.06 3.08 241,753 3.94 0.70 30 2-inch tapered proj. ponded outlet -0.06 2.80 216,816 3.02 0.69 31 2-inch tapered proj. ponded outlet -0.06 2.60 200,177 2.46 0.69 32 2-inch tapered proj. ponded outlet -0.06 2.39 185,157 1.96 0.72 33 2-inch tapered proj. ponded outlet -0.06 1.20 85,493 0.80 0.71 34 2-inch tapered proj. ponded outlet -0.06 0.54 56,958 0.50 0.68 35 2-inch tapered proj. ponded outlet -0.06 1.19 98,551 1.39 0.73 Table C-5. Slip-lined circular culvert outlet control performance data: 4-inch tapered projecting end. Run Entrance Approach Control So Q Re Hw/D ke [%] [cfs] [] [] [] 36 4-inch tapered proj. ponded outlet 0.03 3.00 225,301 4.27 0.68 37 4-inch tapered proj. ponded outlet 0.03 2.86 217,791 3.57 0.68 38 4-inch tapered proj. ponded outlet 0.03 2.59 196,854 2.76 0.70 39 4-inch tapered proj. ponded outlet 0.03 2.43 189,391 1.95 0.71 40 4-inch tapered proj. ponded outlet 0.03 2.27 172,335 1.39 0.71 41 4-inch tapered proj. ponded outlet 0.03 1.14 75,812 0.77 0.62 42 4-inch tapered proj. ponded outlet 0.03 0.81 64,326 0.61 0.61 43 4-inch tapered proj. ponded outlet 0.03 0.48 45,319 0.46 0.62 44 4-inch tapered proj. ponded outlet 0.03 1.94 122,401 1.12 0.68