Unfortunately, this book can't be printed from the OpenBook. If you need to print pages from this book, we recommend downloading it as a PDF.
Visit NAP.edu/10766 to get more information about this book, to buy it in print, or to download it as a free PDF.
« Previous: Appendix F - Calculations for Peak Bending Strain in Pipe Wall for Simulated Field Test
Suggested Citation:"Appendix G - Soil Pressure and Strain Gage Measurements for Simulated Field Test." National Academies of Sciences, Engineering, and Medicine. 2018.
Field Performance of Corrugated Pipe Manufactured with Recycled Polyethylene Content. Washington, DC: The National Academies Press. doi: 10.17226/24934.
×
Suggested Citation:"Appendix G - Soil Pressure and Strain Gage Measurements for Simulated Field Test." National Academies of Sciences, Engineering, and Medicine. 2018.
Field Performance of Corrugated Pipe Manufactured with Recycled Polyethylene Content. Washington, DC: The National Academies Press. doi: 10.17226/24934.
×
Suggested Citation:"Appendix G - Soil Pressure and Strain Gage Measurements for Simulated Field Test." National Academies of Sciences, Engineering, and Medicine. 2018.
Field Performance of Corrugated Pipe Manufactured with Recycled Polyethylene Content. Washington, DC: The National Academies Press. doi: 10.17226/24934.
×
Below is the uncorrected machine-read text of this chapter, intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text of each book. Because it is UNCORRECTED material, please consider the following text as a useful but insufficient proxy for the authoritative book pages.
G-1
Soil Pressure and Strain Gage Measurements
for Simulated Field Test
A P P E N D I X G
Figure G-1. Soil pressure cell layout for simulated field test.
G-2
Figure G-2. Pressure measurements for Chamber 1.
Figure G-3. Pressure measurements for Chamber 2.
G-3
Figure G-4. Pressure measurements for Chamber 3.
Next: Appendix H - Additional Data from SEPTA Railroad Field Test »