Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

Appendix B
Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems

Emissions test results were originally reported in the units required by the cognizant agencies at the time. Over time, the reporting units have changed and are now different for each facility. Consequently, direct comparisons and meaningful summaries require converting results into common units. The information in this appendix is standardized to Environmental Protection Agency (EPA) reference conditions (68°F for temperature; 760 mm Hg for pressure; 0 percent for moisture; and 7 percent for residual oxygen content) and conventional EPA regulatory units (ppmdv for gaseous criteria pollutants and acid gases; mg/dsm 3 for particulates; μg/dsm3 for individual elements; and ng/dsm3 at 7 percent O2 for trace organics). In developing this appendix, the committee reviewed the underlying laboratory and field reports to verify the overall accuracy of data reduction and quality assurance warnings. Reported results were compared to database values prior to standardization to eliminate transcription errors and identify errors in data reduction.

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

TABLE B-1 Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Exhaust Gas Characteristics

Temperature (ºF)

 

155

 

 

155

180

208.23

280

100%

 

Flow rate (dsft3/min)

 

149

 

 

149

2,275

6,043

11,493

100%

 

Oxygen (%)

 

162

 

 

162

1.2

12.955

15.1

100%

 

Moisture (%)

 

158

 

 

158

31.3

40.543

56.2

100%

 

Combustion Quality Indicators (ppmdv)

Carbon monoxide

 

35

0

 

35

2

39

62

100%

 

Total hydrocarbons as carbon

 

20

0

 

20

2.6

6.6

9.0

100%

 

Chemical Agents (ng/dsm3)

GB (Sarin)

 

28

28

3.6

0

 

 

 

0%

0.0006

HD (mustard gas)

 

12

12

230

0

 

 

 

0%

0.035

VX

 

0

0

 

0

 

 

 

 

 

Particulates

PM (gr/dsm3)

 

103

0

 

103

0.9

14.7

50

100%

 

PM (gr/dscf)

 

103

103

 

103

0.0004

0.006

0.022

100%

 

CAA Acid Gas HAPs (ppmdv)

Hydrogen chloride

 

60

44

 

16

0.01

11

44.16

27%

11,172

Chlorine gas

 

6

3

(0.03)

0

 

 

 

0%

(30.00)

CAA Trace Element HAPs (μg/dsm3)

Arsenic

(2.3)

49

37

(0.02)

12

1

10

42

24%

 

Beryllium

(4.2)

35

0

 

2

0.008

0.008

0.008

6%

 

Cadmium

(5.6)

35

7

(0.20)

28

0

6

50

80%

 

Cobalt

 

9

0

 

9

0.08

0.23

0.8

100%

 

Chromium (total)

1,000,000

46

0

 

41

0.22

7.4

56

89%

 

Chromium (hexavalent)

(0.83)

20

13

(0.3)

7

0.34

1.8

4.2

35%

 

Mercury

300

43

0

 

26

0.25

7.1

25

60%

0.9

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection

Limit

N

Minimum

Average

Maximum

 

 

CAA Trace Element HAPs (μg/dsm3)

Manganese

 

30

0

 

30

0.43

233

2,105

100%

 

Phosphorus

 

12

0

 

12

84

1,508

5,934

100%

 

Antimony

300

35

28

(0.11)

7

0.16

1.9

5.4

20%

 

Selenium

 

24

0

 

6

0.16

6.2

15

25 %

 

Other Trace Elements (μg/dsm3)

Aluminum

 

9

0

 

9

82

98

125

100%

 

Barium

50,000

42

0

 

34

1

14

86

81%

 

Boron

 

12

0

 

12

0.41

36

257

100%

 

Copper

 

24

0

 

19

0.20

49

294

79%

 

Potassium

 

20

0

 

14

19

1,253

5,940

70%

 

Nickel

(42)

19

0

 

17

0.16

33

216

89%

 

Lead

90

49

0

 

34

0.16

122

1,704

69%

 

Tin

 

24

0

(14)

18

2.0

122

692

75%

 

Thallium

 

35

35

(0.1)

0

 

 

 

0%

 

Vanadium

 

9

9

(0.81)

0

 

 

 

0%

 

Zinc

 

39

0

 

35

7.5

119

488

90%

 

CAA Trace Organic HAPs (ng/dsm3)

4-aminobiphenyl

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

Aniline

(14,000)

12

12

(6,074)

0

 

 

 

0%

(2)

Benzene

(12,000)

39

0

 

23

0.10

17,401

99,286

59%

5

Benzidene

(0.15)

12

12

(9,994)

0

0%

 

 

 

(1)

Bromoform

 

39

0

 

26

0.0002

6,234

18,230

67%

1

Bromomethane

800

21

14

(2,904)

7

3,690

5,320

6,775

33%

1

Butadiene

 

18

18

(11,564)

0

 

 

 

0%

(5)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

CAA Trace Organic HAPs (ng/dsm3)

Carbon tetrachloride

(670)

26

18

(2,219)

8

2,823

26,655

86,623

31%

4

Chloroform

(430)

33

0

 

21

0.0001

8,069

42,304

64%

2

Carbon disulfide

200,000

29

23

(812)

6

14,020

25,127

47,170

21%

8

Dibenzofuran

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

1,3-dichlorobenzene

10,000

12

12

(6,074)

0

 

 

 

0%

(1)

1,4-dichlorobenzene

10,000

12

12

(6,074)

0

 

 

 

0%

(1)

3,3-dichlorobenzidine

 

12

12

(10,974)

0

 

 

 

0%

(1)

Trans-1,3-dichloropropene

(0.029)

15

15

(2,219)

0

 

 

 

0%

(0.5)

3,3-dimethylbenzidene

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

2,4-dinitrotoluene

(110)

12

12

(6,074)

0

 

 

 

0%

(0.8)

Ethlylene dibromide

(0.45)

12

12

(2,336)

0

 

 

 

0%

(0.3)

Ethylbenzene

 

26

19

(403)

7

521

2,016

4,250

27%

0.5

Ethyl chloride

 

18

18

(1,958)

0

 

 

 

0%

(0.7)

Bis(2-ethylhexyl)phthalate

(42,000)

15

10

(6,178)

5

10,723

94,214

272,641

33%

6

N-hexane

 

21

17

(1,958)

4

2,336

2,523

2,682

19%

0.7

Hexachlorobenzene (total)

 

12

12

(6,074)

0

 

 

 

0%

(0.5)

Hexachlorobutadiene

 

12

12

(6,074)

0

 

 

 

0%

(0.5)

Hexachlorocyclopentadiene

5,000

12

12

(6,074)

0

 

 

 

0%

(0.5)

Hexachloroethane

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

Isophorone

 

12

12

(6,074)

0

 

 

 

0%

(1)

Methyl ethyl ketone

80,000

24

20

(10,572)

4

69,856

78,682

92,667

17%

26

Methylene chloride

(2,400)

39

15

(0.00006)

18

0.0004

205,026

3,088,889

55%

58

2-methylphenol [o-cresol]

50,000

15

12

(6,074)

3

77,222

164,605

264,762

20%

37

Naphthalene

 

12

12

(6,074)

0

 

 

 

0%

(1)

Nitrobenzene

800

12

12

(6,074)

0

 

 

 

0%

(1)

4-nitrophenol

 

12

12

(7,722)

0

 

 

 

0%

(1)

Styrene

 

35

19

(1,283)

16

3,947

42,283

514,734

46%

17

1,1,2,2-tetrachloroethane

(170)

27

25

(1,283)

2

2,206

2,206

2,206

7%

0.3

1,1,2-trichloroethane

(630)

18

18

(1,958)

0

 

 

 

0%

(0.4)

Tetrachloroethylene

(21,000)

6

3

(3,349)

3

4,277

16,135

26,476

50%

2

Toluene

300,000

36

0

 

24

0.00

5,960

28,234

67%

0.8

Vinyl bromide

 

9

9

(9,789)

0

 

 

 

0%

(2)

Vinylidene chloride

 

3

3

(2,219)

0

 

 

 

0%

(0.6)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μtg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Caa Trace Organic HAPs (ng/dsm3)

Methyl chloride

 

12

9

(3,527)

3

29,938

1,135,218

3,088,889

25%

541

Vinyl chloride

(1,400)

26

18

(415)

8

996

5,325

21,502

31%

2

Vinyl acetate

 

24

22

(1,324)

2

1,497

1,497

1,497

8%

0.4

Xylene(m & p)

80,000

22

17

(434)

5

456

2,910

5,169

23%

0.7

Xylene(o)

80,000

22

0

 

6

934

2,066

3,676

27%

0.5

Pentachlorophenol (total)

30,000

12

12

(30,370)

0

 

 

 

0%

(3)

Phenol

30,000

12

7

(6,765)

5

7,125

9,632

13,440

42%

2

1,4-benzenediamine

 

12

12

(6,074)

0

 

 

 

0%

(1)

1,2,4-trichlorobenzene

20,000

12

12

(6,074)

0

 

 

 

0%

(0.8)

4-methylphenol [p-cresol]

50,000

3

1

(6,178)

2

51,323

943,503

1,835,683

67%

210

3-methylphenol [m-cresol]

50,000

3

0

 

2

2,780

12,422

22,063

67%

3

Dimethylphthalate

 

9

0

 

8

9,953

30,987

99,942

89%

4

Di-n-butylphthalate

100,000

3

0

 

3

10,811

31,013

66,190

100%

3

Cis-1,3-dichloropropene

(0.029)

3

3

(2,336)

0

 

 

 

0%

(0.5)

Other Trace Organics (ng/dsm3)

Acenaphthene

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

Acenaphthylene

 

12

0

 

1

1,000

1,000

1,000

8%

0.05

Acetone

 

39

 

 

28

0.001

32,851

110,317

72%

14

Acetophenone

100,000

12

11

(6,074)

1

6,828

6,828

6,828

8%

1

2-acetylaminofluorene

 

12

12

(60,739)

0

 

 

 

0%

(7)

3-amino-9-ethycarbazole

 

12

12

(60,739)

0

 

 

 

0%

(7)

Anthracene

 

12

12

(6,074)

0

 

 

 

0%

(0.8)

Aramite

 

12

12

(6,074)

0

 

 

 

0%

(0.4)

Benzoic acid

 

12

12

(60,739)

0

 

 

 

0%

(12)

Benz(a)anthracene

(11)

12

12

(6,074)

0

 

 

 

0%

(0.6)

Bromodichloromethane

 

21

12

(2,937)

9

3,271

6,968

13,440

43%

1

Benzo(b)fluoranthene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

Benzo(j)fluoranthene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

Benzo(k)fluoranthene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

Benzo(g,h,i)perylene

 

12

12

(6,074)

0

 

 

 

0%

(0.5)

Benzo(a)pyrene

(3)

12

12

(6,074)

0

 

 

 

0%

(0.6)

Bromodichloromethane

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μtg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Other Trace Organics (ng/dsm3)

Benzyl alcohol

 

12

12

(6,074)

0

 

 

 

0%

(1)

Benzaldehyde

 

12

10

(6,074)

2

9,438

19,791

30,145

17%

4

Benzenethiol

 

12

12

(60,739)

0

 

 

 

0%

(13)

Biphenyl

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

Bromophenyl-phenylether(4)

 

12

12

(6,074)

0

 

 

 

0%

(0.5)

Butylbenzylphthalate

 

12

12

(6,074)

0

 

 

 

0%

(0.5)

Cis-1,4-dichloro-2-butene

 

21

21

(1,958)

0

 

 

 

0%

(0.4)

Trans-1,4-dichloro-2-butene

 

12

12

(2,336)

0

 

 

 

0%

(0.4)

Cis-1,3-dichloropropene

(2.2)

31

18

(403)

13

478

140,561

898,154

42%

30

4-chloroaniline

 

9

9

(6,074)

0

 

 

 

0%

(1)

Bis(2-chloroethoxy)methane

 

12

12

(6,074)

0

 

 

 

0%

(2)

Bis(2-chloroethyl)ether

(0.16)

12

12

(6,074)

0

 

 

 

0%

(1)

2,2-oxybis(1-chloropropane)

 

12

12

(6,074)

0

 

 

 

0%

(2)

Chlorobenzilate

 

12

12

(6,074)

0

 

 

 

0%

(0.4)

4-chloro-3-methylphenol

 

12

12

(6,074)

0

 

 

 

0%

(1)

1-chloronaphthalene

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

2-chloronaphthalene

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

2-chlorophenol

 

12

12

(6,074)

0

 

 

 

0%

(1)

4-chlorophenyl-phenylether

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Chrysene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

2-chloropropane

 

12

12

(2,336)

0

 

 

 

0%

(0.7)

Chlorobenzenes (total)

 

29

22

(434)

7

539

2,519

3,942

24%

(0.09)

4,4-DDE

 

12

12

(60,739)

0

 

 

 

0%

(5)

Diallate

 

12

12

(11,681)

0

 

 

 

0%

(1)

Dibenz(a,h)anthracene

(0.71)

12

12

(6,074)

0

 

 

 

0%

(0.52)

Dibromochloropropane

 

12

12

(60,739)

0

 

 

 

0%

(6)

di-n-butyl phthalate

100,000

12

12

(6,074)

0

 

 

 

0%

(0.5)

1,2-dichlorobenzene

10,000

12

12

(6,074)

0

 

 

 

0%

(1)

2,4-dichlorophenol

3,000

12

12

(6,074)

0

 

 

 

0%

(0.9)

2,6-dichlorophenol

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

Dichloromethane

 

9

3

(1,958)

6

7,201

9,353

11,797

67%

3

Dibromomethane

 

18

18

(2,219)

0

 

 

 

0%

(0.3)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Other Trace Organics (ng/dsm3)

1,1-dichloroethene

 

25

25

(415)

0

 

 

 

0%

(0.1)

1,2-dichloroethene

 

12

12

(1,958)

0

 

 

 

0%

(0.5)

1,2-dichloropropane

 

27

25

(1,103)

2

1,047,846

1,047,846

1,047,846

7%

223

1,1-dichloroethane

(380)

18

18

(1,958)

0

 

 

 

0%

(0.5)

1,2-dichloroethane

(200)

15

15

(2,219)

0

 

 

 

0%

(0.5)

Dihydrosafrole

 

12

12

(7,722)

0

 

 

 

0%

(1)

Diethylphthalate

800,000

15

12

(6,074)

3

66,190

400,164

933,286

20%

43

P-dimethylaminoazobenzene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

7,12-dimethylbenzo(a)anthracene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

a,a-dimethylphenethyl-amine

 

12

12

(6,074)

0

 

 

 

0%

(1)

2,4-dimethylphenol

 

12

12

(6,074)

0

 

 

 

0%

(1)

Dimethylphthalate

 

12

11

(5,840)

1

41,456

41,456

41,456

8%

5

1,3-dinitrobenzene (m,o,p)

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

4,6-dinitro-2-methylphenol

 

12

12

(6,074)

0

 

 

 

0%

(1)

2,4-dinitrophenol

 

12

12

(30,370)

0

 

 

 

0%

(4)

2,6-dinitrotoluene

 

12

9

(6,074)

3

 

 

 

25%

(0.8)

Dioxathion

 

12

12

(60,739)

0

 

 

 

0%

(3)

Di-n-octylphthalate

 

15

14

(5,988)

1

48,540

48,540

48,540

7%

4

1,2-diphenylhydrazine

(4.5)

12

12

(6,074)

0

 

 

 

0%

(0.6)

Diphenylamine

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

Ethylmethanosulfonate

 

12

12

(6,074)

0

 

 

 

0%

(1)

Ethylparathion

 

12

12

(60,739)

0

 

 

 

0%

(12)

Fluoranthene

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Fluorene

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Freon 12

 

12

12

(2,336)

0

 

 

 

0%

(0.5)

Freon 113

 

18

18

(1,958)

0

 

 

 

0%

(0.3)

2-hexanone

 

27

25

(600)

2

3,500

3,500

3,500

7%

0.8

Heptachlor

(7.7)

12

12

(44,800)

0

 

 

 

0%

(3)

Hexachlorophene

300

12

12

(6,074)

0

 

 

 

0%

(0.4)

Hexachloropropene

 

12

12

(7,095)

0

 

 

 

0%

(0.7)

Indeno(1,2,3-cd)pyrene

 

12

12

(6,074)

0

 

 

 

0%

(0.5)

Isosafrole

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

Methapyrilene

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Other Trace Organics (ng/dsm3)

4-methyl-2-pentanone

 

24

23

(1,283)

1

10,370

10,370

10,370

4%

2

Methoxyclor

50,000

12

12

(60,739)

0

 

 

 

0%

(4)

3-methylcholanthrene

(3.7)

12

12

(6,074)

0

 

 

 

0%

(0.5)

Methylmethanesulfonate

 

12

12

(6,074)

0

 

 

 

0%

(1)

3,4-methylphenanthrene

 

12

12

(6,074)

0

 

 

 

0%

(0.8)

2-methylnaphthalene

 

12

12

(6,074)

0

 

 

 

0%

(1)

2-methyl-5-nitroaniline

 

12

12

(60,739)

0

 

 

 

0%

(11)

1-naphthylamine

 

12

12

(6,074)

0

 

 

 

0%

(1)

2-naphthylamine

 

12

12

(6,074)

0

 

 

 

0%

( 1 )

2-nitrophenol

 

12

12

(6,074)

0

 

 

 

0%

(1)

4-nitroquinoline-1-oxide

 

12

12

(6,074)

0

 

 

 

0%

(0.6)

N-nitrozo-di-n-butylamine ng/dsm3

 

12

12

(6,074)

0

 

 

 

0%

(1)

N-nitroso-di-n-propylamine

 

12

12

(6,074)

0

 

 

 

0%

(1)

N-nitrosodiethylamine

(0.23)

12

12

(6,074)

0

 

 

 

0%

(1)

N-nitrosodimethylamine

 

12

12

(6,074)

0

 

 

 

0%

(2)

N-nitrophenylamine

 

12

12

(6,074)

0

 

 

 

0%

(1)

1,4-naphthoquinone

 

12

12

(6,074)

0

 

 

 

0%

(1)

5-nitroacenaphthene

 

12

12

(60,739)

0

 

 

 

0%

(7)

2-nitroaniline

 

12

12

(35,474)

0

 

 

 

0%

(6)

3-nitroaniline

 

12

12

(35,474)

0

 

 

 

0%

(6)

4-nitroaniline

 

12

12

(35,474)

0

 

 

 

0%

(6)

2-propanol

 

12

12

(230,226)

0

 

 

 

0%

(92)

1,1,1,2-tetrachloroethane

 

12

12

(2,336)

0

 

 

 

0%

(0.5)

Trans-1,2-dichloroethane

(38)

15

15

(1,958)

0

 

 

 

0%

(0.5)

Trichloroethane

 

3

3

(2,219)

0

 

 

 

0%

(0.4)

1,1,1-trichloroethane

 

31

26

(403)

5

479

9,131

20,416

16%

2

Tetrachloroethene

 

31

22

(403)

9

428

2,814

8,541

29%

0.4

Trichlorofluoromethane

300,000

18

18

(1,958)

0

 

 

 

0%

(0.3)

1,1,2-trichloroethene

 

7

6

(0)

1

0.0003

0.0003

0.0003

14%

0.00000005

Trichloroethylene

(7,700)

15

15

(1,958)

0

 

 

 

0%

(0.4)

1,2,3-chloropropane

 

3

3

(3,349)

0

 

 

 

0%

(1)

Trans-1,3-dichloropropene

(0.029)

15

15

(2,219)

0

 

 

 

0%

(0.5)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Other Trace Organics (ng/dsm3)

Bromoethane

 

9

9

(11,564)

0

 

 

 

0%

(3)

N-nitrosomethylethylamine

 

12

12

(6,074)

0

 

 

 

0%

(2)

N-nitrosomorpholine

 

12

12

(6,074)

0

 

 

 

0%

(1)

N-nitrosopiperidine

 

12

12

(6,074)

0

 

 

 

0%

(1)

N-nitrosopyrrolidine

(16)

12

12

(6,074)

0

 

 

 

0%

(2)

5-nitro-o-toluidine

 

12

12

(6,074)

0

 

 

 

0%

(1)

Pentachlorobenzene (total)

800

12

12

(7,095)

0

 

 

 

0%

(0.7)

Penthachloroethane

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Pentachloronitrobenzene

(140)

12

12

(30,370)

0

 

 

 

0%

(3)

Phenacetin

 

12

12

(6,074)

0

 

 

 

0%

(0.8)

Phenanthrene

 

12

11

(6,074)

1

8,752

8,752

8,752

8%

1

2-picoline

 

12

12

(6,074)

0

 

 

 

0%

(2)

Pronamide

(2,200)

12

12

(6,074)

0

 

 

 

0%

(0.6)

Pyrene ·

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Pyridine

1,000

12

12

(11,681)

0

 

 

 

0%

(4)

Quinoline

 

12

12

(60,739)

0

 

 

 

0%

(11)

Safrole

 

12

12

(6,074)

0

 

 

 

0%

(0.9)

1,2,4,5-tetrachlorobenzene

300

12

12

(6,074)

0

 

 

 

0%

(0.7)

2,3,4,6-tetrachlorophenol

30,000

12

12

(30,370)

0

 

 

 

0%

(3)

P-toludine

 

12

12

(60,739)

0

 

 

 

0%

(14)

2-toluidine

 

12

12

(6,074)

0

 

 

 

0%

(1)

Tributylamine

 

12

12

(60,739)

0

 

 

 

0%

(8)

2,4,5-trichlorophenol

100,000

12

12

(6,074)

0

 

 

 

0%

(0.7)

2,4,6-trichlorophenol

(1,800)

12

12

(6,074)

0

 

 

 

0%

(0.7)

0,0,0-triethylphosphorothioate

 

12

12

(60,739)

0

 

 

 

0%

(10)

1,3,5-trinitrobenzene

 

12

12

(6,074)

0

 

 

 

0%

(0.7)

Chloromethane

28,000

12

9

(3,349)

3

705,692

786,818

904,603

25%

375

Total xylene

80,000

3

2

(1,283)

1

1,986

1,986

1,986

33%

0.4

Trans-l,2-dichloroethylene

 

3

3

(2,336)

0

 

 

 

0%

(0.6)

N,n'-diisopropylcarbodiimide

 

6

6

(52,000)

0

 

 

 

0%

(10)

Diisopropylmethylphosphonate

 

6

6

(60,739)

0

 

 

 

0%

(10)

1,2,3-trichlorophenol

 

6

6

(2,000)

0

 

 

 

0%

(0.2)

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

 

Risk-Specific Dose or Reference Air Concentration (RsD or RAC)a

Total Runs

Nondetects Lower than Lowest Detected Valuesb

Detected Values Only

Detected Values

Average or DL ppbdv

Values are at 7% O2 Unless Otherwise Specified

μg/m3

N

N

Detection Limit

N

Minimum

Average

Maximum

 

 

Polychlorinated Dibenzo-P-Dioxins and Dibenzo Furans (ng/dsm3)

2,3,7,8-tetrachlorodibenzo-p-dioxin

(0.00022)

32

31

(0.0002)

1

0.002

0.002

0.002

3%

0.0000002

Tetrachlorodibenzo-p-dioxins (total)

 

47

13

(0.0004)

36

0.001

0.110

0.968

72%

0.000008

2,3,7,8-tetrachlorodibenzofuran

 

32

9

(0.002)

26

0.003

0.015

0.066

74%

0.000001

Tetrachlorodibenzofurans (total)

 

50

0

 

51

0.004

0.208

1.244

96%

0.00002

1,2,3,7,8-pentachlorodibenzo-p-dioxin

 

32

32

(0.001)

0

 

 

 

0%

(0.0000001)

Pentachlorodibenzo-p-dioxins (total)

 

43

28

(0.001)

15

0.005

0.181

0.877

33%

0.00001

1,2,3,7,8-pentachlorodibenzofuran

 

32

30

(0.001)

2

0.054

0.064

0.074

6%

0.000005

2,3,4,7,8-pentachlorodibenzofuran

 

32

29

(0.0005)

3

0.041

0.086

0.159

9%

0.000006

Pentachlorodibenzofurans (total)

 

47

17

(0.001)

30

0.004

0.357

1.815

60%

0.00003

1,2,3,4,7,8-hexachlorodibenzo-p

dioxin

(0.0077)

32

32

(0.0002)

0

 

 

 

0%

 

(0.00000001)

 

 

 

 

 

 

 

 

 

 

1,2,3,6,7,8-hexachlorodibenzo

p-dioxin

(0.0077)

32

32

(0.0001)

0

 

 

 

0%

 

(0.00000001)

 

 

 

 

 

 

 

 

 

 

1,2,3,7,8,9-hexachlorodibenzo-p

dioxin

(0.0077)

32

31

(0.0002)

6

0

0.0211

0.1269

17%

0.000001

Hexachlorodibenzo-p-dioxins (total)

 

47

28

(0.0002)

19

0.006

0.528

2.860

38%

0.00003

1,2,3,4,7,8-hexachlorodibenzofuran

 

32

27

(0.0002)

5

0.12

0.20

0.31

14%

0.00001

1,2,3,6,7,8-hexachlorodibenzofuran

 

32

28

(0.0001)

9

0

0.0283

0.0861

26%

0.000002

1,2,3,7,8,9-hexachlorodibenzofuran

 

32

32

(0.0002)

0

 

 

 

0%

 

(0.00000001)

 

 

 

 

 

 

 

 

 

 

2,3,4,6,7,8-hexachlorodibenzofuran

 

32

27

(0.0002)

10

0

0.0212

0.1776

29%

0.000001

Hexachlorodibenzofurans (total)

 

47

20

(0.0003)

27

0.0059

0.3394

1.1381

54%

0.00002

1,2,3,4,6,7,8-heptachlorodibenzo-p

dioxin

 

32

23

(0.0004)

9

0.0051

0.0777

0.2982

26%

0.000004

Heptachlorodibenzo-p-dioxins (total)

 

47

28

(0.0004)

19

0.005

0.281

1.047

38%

0.00002

1,2,3,4,6,7,8-heptachlorodibenzofuran

 

32

25

(0.0003)

7

0.0051

0.0887

0.1822

20%

0.000005

1,2,3,4,7,8,9-heptachlorodibenzofuran

 

32

28

(0.0001)

9

0

0.0576

0.2157

26%

0.000003

Heptachlorodibenzofurans (total)

 

44

17

(0.0003)

27

0.007

0.204

1.138

57%

0.00001

Octachlorodibenzo-p-dioxin

 

47

27

(0.002)

20

0.015

0.183

0.634

40%

0.00001

Octachlorodibenzofuran

 

50

42

(0.001)

8

0.018

0.152

0.426

15%

0.000008

Total dioxins & furans

 

40

0

 

40

0.010

1.372

8.645

100%

0.00009

International toxic equivalency ( 1989

 

36

36

 

39

0.001

0.037

0.206

100%

0.000003

ITEQ calculated setting all BDL values to 0

 

35

0

 

35

0.0

0.010

0.131

100%

0.000001

a Average annual reference air concentrations (RAC) and risk specific dose (RsD) values in μg/m3 are taken from 40 CFR 266, Appendices IV and V. RsD values are shown in parentheses. The RAC is 0.1 μg/m3 for SOPCs without a pollutant-specific RAC or RsD. Since the emitted concentration ranges are between 642,000 (MPF), 919,000 (LIC), and 1,350,000 (DFS) times greater than the annual average concentration represented by the RAC and RsD, to compare these inhalation pathway-based concentrations with measured concentrations and detection limits, multiply the RAC or RsD by 1,000,000 for particulates and metals. The multiplier for trace organic emissions is 1,000,000,000 to account for the difference in reported units.

b Nondetected concentrations with detection limits above detected values for other sampling intervals have been excluded from the table to facilitate summary presentation of the data. To determine the number of these runs, subtract the number of detects and nondetects less than the lowest detected value from the total number of runs.

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

Source: Compiled from data in sources listed below.

JACADS Data Sources:

Metco Environmental. 1992a. Source Emissions Survey of Johnston Atoll Chemical Agent Disposal System Liquid Incinerator Stack [LIC/GB]. Prepared for Southern Research Institute, August 1992. Addison, Texas: Metco Environmental.

Metco Environmental. 1992b. Source Emissions Survey of Johnston Atoll Chemical Agent Disposal System Liquid Incinerator Stack [LIC/VX], February and March 1992. Prepared for Southern Research Institute, February 1992. Addison, Texas: Metco Environmental.

Raytheon Engineers & Constructors, Inc. 1995. RCRA Trial Burn Report for Agent GB/Dunnage, in the Dunnage Incinerator at the Johnston Atoll Chemical Agent Disposal System [DUN/GB]. Prepared for Program Manager for Chemical Demilitarization, March 1995. Philadelphia, Pa.: Raytheon Engineers & Constructors, Inc.

SRI. 1991. Results of the RCRA Trial Burn with GB Feed for the Liquid Incinerator at the Johnston Atoll Chemical Agent Disposal System [LIC/GB]. Prepared for Program Manager for Chemical Demilitarization, June 17, 1991. Birmingham, Ala.: Southern Research Institute.

SRI (Southern Research Institute). 1992a. Results of the RCRA Trial Burn with VX Feed for the Liquid Incinerator at the Johnston Atoll Chemical Agent Disposal System, Volume IV (SRI-APC-92-384-7530.11.1-I) [LIC/VX]. Prepared for Program Manager for Chemical Demilitarization. Birmingham, Ala.: Southern Research Institute.

SRI. 1992b. Results of the RCRA Trial Burn of the Metal Parts Furnace System with HD at the Johnston Atoll Chemical Agent Disposal System, Volume II (SRI-APC-92-834-7530.9.l-I) [MPF/HD]. Prepared for Program Manager for Chemical Demilitarization. Birmingham, Ala.: Southern Research Institute.

SRI. 1992c. Results of the RCRA Demonstration Burn with HD Feed for the Liquid Incinerator at the Johnson Atoll Chemical Agent Disposal System, Volume IV, Appendix F (SRI-APC-92-7530.10.1-I) [LIC/HD]. Prepared for Program Manager for Chemical Demilitarization. Birmingham, Ala.: Southern Research Institute.

United Engineers (United Engineers & Constructors, Inc.). 1992. RCRA Trial Burn Report for HD-Mustard Ton Containers-Metal Parts Furnace at the Johnston Atoll Chemical Agent Disposal System [MPF/HD]. Prepared for Program Manager for Chemical Demilitarization, December 16, 1992. Philadelphia, Pa.: United Engineers & Constructors, Inc.

United Engineers. 1993. Results of the Demonstration Test Burn for Thermal Destruction of Agent HD in the Johnston Atoll Chemical Agent Disposal System Liquid Incinerator, [LIC/HD]. Prepared for Program Manager for Chemical Demilitarization, February 1993. Philadelphia, Pa.: United Engineers & Constructors, Inc.

TOCDF Data Sources:

Alliance Technologies Corporation. 1992. RCRA Compliance Test Results with Mixed Agent HD/Munitions for the Cryofracture Program on the Deactivation Furnace System, Chemical Agent Munitions Disposal System [DSF/HD]. Prepared for Program Manager for Chemical Demilitarization. Windsor, Conn.: TRC Environmental Corp.

EG&G. 1995. Tooele Chemical Disposal Facility (TOCDF), Surrogate Trial Burn Report for Liquid Incinerator Number 1 [LIC/STB]. Prepared for Program Manager for Chemical Demilitarization, November 29, 1995. Tooele, Utah: EG&G Defense Materials, Inc.

EG&G. 1997a. MPF GB ATB Report, Rev. 2 (partial report), [MPF/GB]. Prepared for Southern Research Institute, December 31, 1997a. Tooele, Utah: EG&G Defense Materials, Inc.

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×

EG&G. 1997b. Tooele Chemical Agent Disposal Facility (TOCDF), RCRA Agent Trial Burn Report for the Liquid Incinerator System #2 [LIC/GB]. Prepared for Southern Research Institute, October 27, 1997. Tooele, Utah: EG&G Defense Materials, Inc.

EG&G. 1997c. Tooele Chemical Agent Disposal Facility (TOCDF), RCRA Agent Trial Burn Report for the Metal Parts Furnace, Appendices A-K [MPF/GB]. Prepared for Program Manager for Chemical Demilitarization, August 15, 1997. Tooele, Utah: EG&G Defense Materials, Inc.

EG&G. 1997d. Tooele Chemical Agent Disposal Facility (TOCDF), RCRA Agent Trial Burn Report for the Liquid Incinerator System #1, Appendices A-K, [LIC/GB]. Prepared for Program Manager for Chemical Demilitarization, July 7, 1997. Tooele, Utah: EG&G Defense Materials, Inc.

EG&G. 1997e. Tooele Chemical Agent Disposal Facility (TOCDF), DFS TSCA Demonstration Test Burn Report for the Deactivation Furnace System [DFS/GB]. Prepared for Program Manager for Chemical Demilitarization, April 24, 1997. Tooele, Utah: EG&G Defense Materials, Inc.

EG&G. 1997f. Tooele Chemical Agent Disposal Facility (TOCDF), RCRA Agent GB Trial Burn Report for the Deactivation Furnace System [DFS/GB], Appendices A-J. Prepared for Program Manager for Chemical Demilitarization, April 9, 1997. Tooele, Utah: EG&G Defense Materials, Inc.

EG&G (EG&G Defense Materials, Inc.). 1998. Tooele Chemical Agent Disposal Facility (TOCDF), RCRA Agent Trial Burn Report for the Deactivation Furnace System [DSF/ GB]. Prepared for Southern Research Institute, January 14, 1998. Tooele, Utah: EG&G Defense Materials, Inc.

TRC (TRC Environmental Corporation). 1993a. Results of the Chromium Emissions Test Program on the Deactivation Furnace System Baseline Test Conditions, Chemical Agent Munitions Disposal System (CAMDS), Tooele, Utah [DFS/Propane]. Prepared for Program Manager for Chemical Demilitarization, May 1993. Aberdeen Proving Ground, Md.: U.S. Army Program Manager for Chemical Demilitarization.

TRC. 1993. RCRA Compliance Test Results with Mixed Agent VX/Munitions for the Cryofracture Program on the Deactivation Furnace System, Chemical Agent Munitions Disposal System [DFS/VX]. Prepared for Program Manager for Chemical Demilitarization, October 1993. Aberdeen Proving Ground, Md.: U.S. Army Program Manager for Chemical Demilitarization.

Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 58
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 59
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 60
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 61
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 62
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 63
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 64
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 65
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 66
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 67
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 68
Suggested Citation:"Appendix B Consolidated Exhaust Gas Characteristics for the JACADS and TOCDF Baseline Incineration Systems." National Research Council. 1999. Carbon Filtration for Reducing Emissions from Chemical Agent Incineration. Washington, DC: The National Academies Press. doi: 10.17226/9651.
×
Page 69
Next: Appendix C Commercial Application of Carbon Bed Filters to Combustion Sources »
Carbon Filtration for Reducing Emissions from Chemical Agent Incineration Get This Book
×
Buy Paperback | $51.00 Buy Ebook | $40.99
MyNAP members save 10% online.
Login or Register to save!
Download Free PDF

This report reviews the Army's evaluation of carbon filters for use in the baseline incineration PAS, as well as the Army's change management process (the Army's tool for evaluating major equipment and operational changes to disposal facilities). In preparing this report, members of the Stockpile Committee evaluated exhaust gas emissions testing at the two operating baseline incineration systems, JACADS and the TOCDF; evaluated the development of the dilute SOPC carbon filter simulation model; and evaluated the conceptual design of a modified PAS with an activated carbon filter. The two major risk assessments conducted for each continental disposal site that use the baseline system, namely, (1) the quantitative risk assessment, which evaluates the risks and consequences of accidental agent releases, and (2) the health risk assessment, which evaluates the potential effects of nonagent emissions on human health and the environment, were also examined.

  1. ×

    Welcome to OpenBook!

    You're looking at OpenBook, NAP.edu's online reading room since 1999. Based on feedback from you, our users, we've made some improvements that make it easier than ever to read thousands of publications on our website.

    Do you want to take a quick tour of the OpenBook's features?

    No Thanks Take a Tour »
  2. ×

    Show this book's table of contents, where you can jump to any chapter by name.

    « Back Next »
  3. ×

    ...or use these buttons to go back to the previous chapter or skip to the next one.

    « Back Next »
  4. ×

    Jump up to the previous page or down to the next one. Also, you can type in a page number and press Enter to go directly to that page in the book.

    « Back Next »
  5. ×

    Switch between the Original Pages, where you can read the report as it appeared in print, and Text Pages for the web version, where you can highlight and search the text.

    « Back Next »
  6. ×

    To search the entire text of this book, type in your search term here and press Enter.

    « Back Next »
  7. ×

    Share a link to this book page on your preferred social network or via email.

    « Back Next »
  8. ×

    View our suggested citation for this chapter.

    « Back Next »
  9. ×

    Ready to take your reading offline? Click here to buy this book in print or download it as a free PDF, if available.

    « Back Next »
Stay Connected!