Skip to main content

Currently Skimming:

Appendix C - Simple Performance Test Specimen Fabrication System Specification
Pages 138-142

The Chapter Skim interface presents what we've algorithmically identified as the most significant single chunk of text within every page in the chapter.
Select key terms on the right to highlight them within pages of the chapter.


From page 138...
... 138 A P P E N D I X C Simple Performance Test Specimen Fabrication System Specification
From page 139...
... 139 NCHRP 9-29 First Article Equipment Specification for Simple Performance Test Specimen Fabrication Equipment Version 2.0 June, 29, 2007 Table of Contents Table of Contents ................................................................................................................................139 1.0 Summary .....................................................................................................................................140 2.0 Definitions.....................................................................................................................................140 3.0 Simple Performance Test Specimen Fabrication System............................................................140 4.0 Simple Performance Test Specimen Requirements .....................................................................141 5.0 Documentation ...............................................................................................................................141 6.0 Warranty........................................................................................................................................141
From page 140...
... 3.2 The Simple Performance Test Specimen Fabrication System shall be designed so that a skilled technician can prepare a simple performance test specimen from an existing gyratory specimen in 15 minutes or less. 3.3 The Simple Performance Test Specimen Fabrication System shall be designed to handle 150 mm (6 in)
From page 141...
... 4.3 Test specimens shall conform to the requirements of Table 1. 5.0 Documentation 5.1 A reference manual completely documenting the Simple Performance Test Specimen Fabrication System shall be provided.
From page 142...
... Item Specification Note Average Diameter 100 mm to 104 mm 1 Standard Deviation of Diameter 0.5 mm 1 Height 147.5 mm to 152.5 mm 2 End Flatness 0.5 mm 3 Specimen Dimensions End Perpendicularity 1.0 mm 4 Notes: 1. Using calipers, measure the diameter at the center and third points of the test specimen along axes that are 90 apart.


This material may be derived from roughly machine-read images, and so is provided only to facilitate research.