Skip to main content

Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe

View Cover

Overview

Contributors

Description

Ductile iron pipe (DIP) was introduced about 50 years ago as a more economical and better-performing product for water transmission and distribution. As with iron or steel pipes, DIP is subject to corrosion, the rate of which depends on the environment in which the pipe is placed. Corrosion mitigation protocols are employed to slow the corrosion process to an acceptable rate for the application. When to use corrosion mitigation systems, and which system, depends on the corrosivity of the soils in which the pipeline is buried.

The Bureau of Reclamation's specification for DIP in highly corrosive soil has been contested by some as an overly stringent requirement, necessitating the pipe to be modified from its as-manufactured state and thereby adding unnecessary cost to a pipeline system.

This book evaluates the specifications in question and presents findings and recommendations. Specifically, the authoring committee answers the following questions:

  • Does polyethylene encasement with cathodic protection work on ductile iron pipe installed in highly corrosive soils?
  • Will polyethylene encasement and cathodic protection reliably provide a minimum service life of 50 years?
  • What possible alternative corrosion mitigation methods for DIP would provide a service life of 50 years?

Topics

Suggested Citation

National Research Council. 2009. Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe. Washington, DC: The National Academies Press. https://doi.org/10.17226/12593.

Import this citation to:

Publication Info

186 pages | 7 x 10
ISBNs:
  • Paperback: 978-0-309-13163-6
  • Ebook: 978-0-309-14788-0
DOI: https://doi.org/10.17226/12593
Contents
Rights

Copyright Information

The National Academies Press and the Transportation Research Board have partnered with Copyright Clearance Center to offer a variety of options for reusing our content. You may request permission to:

  • Republish or display in another publication, presentation, or other media
  • Use in print or electronic course materials and dissertations
  • Share electronically via secure intranet or extranet
  • And more

For most Academic and Educational uses no royalties will be charged although you are required to obtain a license and comply with the license terms and conditions.

Click here to obtain permission for Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe.

Translation and Other Rights

For information on how to request permission to translate our work and for any other rights related query please click here.

Copyright.com Customer Service

For questions about using the Copyright.com service, please contact:

Copyright Clearance Center
22 Rosewood Drive
Danvers, MA 01923
Tel (toll free): 855/239-3415 (select option 1)
E-mail: info@copyright.com
Web: https://www.copyright.com
Stats

Loading stats for Review of the Bureau of Reclamation's Corrosion Prevention Standards for Ductile Iron Pipe...