Below is the uncorrected machine-read text of this chapter, intended to provide our own search engines and external engines with highly rich, chapter-representative searchable text of each book. Because it is UNCORRECTED material, please consider the following text as a useful but insufficient proxy for the authoritative book pages.
C-1 APPENDIX C SAMPLE DATA COLLECTION SPREADSHEETS
C-2 Test # Date Device # Time Begin Time End Humidity (%) Temp Test Details T1 T2 Test Contaminant Contaminated Sample Alarm Results Notes 18 3/1/2003 20661 11:59 12:19 49 24.0 Handle 1 61 14 Semtex - 50 ng FALSE FALSE NO ALARM In a service corridor, outside of multiple doors- #42, staff security room, 427 rest room, 439 electrical room, on a cement floor. Handle 2 43 13 FALSE FALSE NGN Handle 3 45 15 FALSE FALSE NO ALARM Handle 4 44 16 FALSE FALSE NGN Handle 5 44 15 FALSE FALSE NO ALARM Handle 6 42 15 FALSE FALSE NGN Handle 7 44 15 FALSE FALSE NO ALARM Handle 8 39 15 FALSE FALSE NO ALARM Handle 9 40 14 FALSE FALSE NO ALARM Handle 10 37 15 TRUE TRUE SEMTEX 3 PETN-C PETN-F RDX-C RDX-CS RDX-N VER-PF BLANK 30 16 FALSE TRUE TATP 1 FALSE FALSE TATP-S BLANK 24 16 FALSE TRUE TATP 1 FALSE FALSE TATP-S
C-3 Test # Date Device # Time Begin Time End Humidity (%) Temp Test Details T1 T2 Test Contaminant Contaminated Sample Alarm Results Notes BLANK 37 15 FALSE FALSE NO ALARM 2 14 FALSE FALSE NGN Zipper 10 Zipper 9 49 4 14 FALSE FALSE NO ALARM 21 3/1/2003 20661 13:11 13:24 48 22.8 Handle 1 24 15 Semtex - 50 ng TRUE TRUE SEMTEX 4 Inside the holding room on the lower platform. Outside of custodial room 132, on concrete. PETN-C PETN-F PETN-N RDX-C RDX-CS RDX-N BLANK 46 16 FALSE TRUE TATP 1 FALSE FALSE TATP-S BLANK 43 16 FALSE FALSE NO ALARM Handle 2 40 14 FALSE FALSE NGN Handle 3 43 14 FALSE FALSE NO ALARM Handle 4 41 14 FALSE FALSE NO ALARM Handle 5 41 14 FALSE FALSE NGN Handle 6 44 14 FALSE FALSE NO ALARM Handle 7 45 14 FALSE FALSE NO ALARM Handle 8 42 15 FALSE FALSE NGN Handle 9 43 15 FALSE FALSE NO ALARM
C-4 Test # Date Device # Time Begin Time End Humidity (%) Temp Test Details T1 T2 Test Contaminant Contaminated Sample Alarm Results Notes Handle 10 42 15 FALSE FALSE NGN 22 3/1/2003 20661 14:54 15:10 50 21.0 Zipper 1 8 15 Semtex - 50 ng FALSE FALSE NGN Mezzanine level between escalators, medium breeze and heavy commuter traffic. Zipper 2 5 15 FALSE FALSE NO ALARM Zipper 3 6 14 FALSE FALSE NO ALARM 8 14 FALSE FALSE NGN Zipper 5 Zipper 4 5 14 FALSE FALSE NO ALARM 3 14 FALSE FALSE NGN Zipper 7 2 15 FALSE FALSE NO ALARM 5 15 FALSE FALSE NGN Zipper 9 Zipper 8 Zipper 6 7 15 FALSE FALSE NO ALARM Zipper 10 42 4 4 4 4 4 5 4 4 4 15 TRUE TRUE C4/RDX 4 PETN-C RDX-C RDX-CS BLANK 26 14 FALSE TRUE TATP 1 FALSE FALSE TATP-S BLANK 39 15 FALSE FALSE NO