... O-1 A P P E N D I X O AASHTO Test Method
From page 227...
... O-2 Standard Method of Test for Adhesive Anchors in Concrete AASHTO Designation: T XXXX-XX Prior to possible addition of SvTTF: Refer to ACI 355.4-11 for testing of adhesive anchors in concrete with the following exceptions: ACI 355.4 §8.5.2.3 shall read as follows: Qualify anchors for one or both of the temperature categories given in Table 8.1. The minimum long-term temperature for which anchors shall be qualified is 110°F.
From page 228...
... O-3 d) Continuous mixing in a nozzle but do not provide information in the MPII that addresses delays in the automatic mixing process that might occur during anchor installation (e.g., setting the injection system aside while an anchor is installed and then reinitiating adhesive injection some minutes later)