From page 70...
... 70 PM Measurement Instruments The particle measurement instruments used during this research are listed in Table H-1 and include a MAAP (Model 5012, Thermo Scientific) , a CAPS-based particle extinction monitor (PMex)
From page 71...
... PM Measurement Instruments 71 The CAPS technique, similar in nature to cavity ring-down spectroscopy, relies on the use of a sample cell employing high reflectivity mirrors. In this particular application, square-wave modulated red light (~635 nm)
From page 72...
... 72 Exhaust Emissions from In-Use General Aviation Aircraft spectro meter operates at 10 L/min, which greatly reduces particle sampling losses due to diffusion. Additionally, it operates at ambient pressure to eliminate any concern about evaporating volatile and semi-volatile particles.